Abstract: Following the discovery of discontinuities in a weld specimen, which was made with a process called narrow gap electroslag welding (ESW-NG), the specimen was subject to mechanical cyclical tension loading until failure. The loading involved one block of 100 tension-only cycles at 42 ksi peak stress followed by a second block of 20 tension-only cycles at 55 ksi stress. Phased Array Ultrasonic Testing (PAUT) was performed to understand whether or not the loading protocol has caused the internal discontinuities to increase in length. The PAUT was performed before cycling began and after the end of first block of cycles. Conventional Ultrasonic Testing was also performed in order to develop comparative baseline results. PAUT utilizes an aperture, which is composed of multiple individual small transducer elements which can be pulsed individually at a computer-calculated timing (“phased or delay laws”) producing a sound beam which is swept through a volume of material. Utilizing PAUT, the operator has the ability to “steer” and “focus” the beam electronically through the material being examined at multiple angles in one scan (for example 45° through 75°) in lieu of being fixed at a certain angle as in conventional Ultrasonic testing (UT). The PAUT equipment utilized has the capabilities of 16 active pulsars capable of multiplexing over 64 channels (16:64) displayed in A, B, C, S, Linear scans, or a combination thereof. Scanning with a digital encoder was utilized in order to collect the data for post processing, analysis and data documentation. This presentation will discuss the findings of the PAUT on this weld specimen. The PAUT aperture utilized was a 5L-60 with 1 mm pitch and Sectorial and Linear scans were utilized. The sectorial scan results of the PAUT before and after cycling showed an increase in dimensions of the recorded indications by an average of 6–8 mm or approximately 50% of the original dimensions. The presentation will also include a discussion of the advantages and limitations of PAUT for various bridge applications. The advantages of PAUT include speed, flexibility, and the ability to perform complex inspections.
Keywords: Ultrasonic Testing, Phased Array Ultrasonic Testing, Electroslag, Non-Destructive Testing
DOI: 10.3233/BRS-180124
Journal: Bridge Structures, vol. 13, no. 4, pp. 135-146, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]