Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chan, Ben Y.B. | Cheung, Moe M.S. | Wang, Chao
Affiliations: Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology, Hong Kong
Note: [] Corresponding author. Moe M.S. Cheung, Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology, Hong Kong. E-mail: [email protected]
Abstract: The central span which is the most critical part of a cable-stayed bridge has almost reached the technical limit for traditional materials, construction technology and bridge system capability. The idea of Ultra-long Span Cable Stayed Bridge (USCSB) is proposed in this paper by introducing a hybrid type cable stayed bridge as a competent system. The new system leads to huge reduction in deck weight and critical stresses in the pylon zones by using a hybrid advanced composite deck. A multi-scale modeling technique is adapted which represent material design at the micro/macro-level, and accurate homogenization of the advanced composite components properties and evaluation of the resulting anisotropic characteristics. Besides, the dynamic performance under wind and seismic excitations, and the potential deficiency of such a bridge system is investigated via state-of-the-art computer simulations and large-scale dual shaking table experiments. The investigation result demonstrated that adopting a fiber reinforced polymer deck system can efficiently reduce internal deck stresses due to the high strength of FRP materials and the tubular type of lay-up structural system, increase its load carrying capacity of cable stayed bridges and hence, having a great potential extent the span length of stay cable supported bridge system. At the same time, due to the relatively low Young's modulus and shear modulus of fibrous materials, deflection at full loading and torsional resistance should be carefully controlled by using a convex initial configuration with sufficient internal bracing. Moreover, investigation result also suggested that wind induced coupling excitation is likely to occur in such a light-weighted system with low shear and torsional stiffness.
Keywords: Fiber reinforced plastics, cable stayed bridge, multi-scale design, full bridge model, shake table test
DOI: 10.3233/BRS-130048
Journal: Bridge Structures, vol. 9, no. 1, pp. 3-19, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]