Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Garapati, S.H. | Kaw, A.
Affiliations: Department of Mechanical Engineering, University of South Florida, Tampa, FL, USA
Note: [] Corresponding author. A. Kaw, Department of Mechanical Engineering, University of South Florida, Tampa, 4202 E. Fowler Avenue, ENB 118, Tampa, FL 33620-5350, USA. Tel.: +1 813 974 5626; Fax: +1 813 974 3539; E-mail: [email protected]
Abstract: Assembly procedures for assembling steel fulcra of simple-trunnion bascule bridges by heating the girder with heating coils instead of dipping an already stressed trunnion-hub assembly in liquid nitrogen are studied for decreasing the likelihood of failure by cracking and yielding. In the assembly procedure called AP3-A, only the girder is heated to shrink-fit the trunnion-hub assembly in the girder. This assembly procedure AP3-A is found to be infeasible because the girder fails by yielding if heating is expected to be completed in a reasonable amount of time. An alternative assembly procedure called AP3-B is suggested for shrink-fitting where the heating of the girder is combined with cooling the trunnion-hub assembly in dry-ice/alcohol mixture. This assembly procedure AP3-B is found to be feasible. A complete design of experiments study is conducted on AP3-B to find the influence of parameters like hub radial thickness, and radial interference at trunnion-hub interface on the design parameter of critical crack length – a measure of likelihood of fracture. Critical crack lengths during the assembly procedure AP3-B are quantitatively compared with currently used assembly procedures. The results of this work suggest that increasing the hub radial thickness decreases the likelihood of fracture significantly. For hubs with large radial thickness, heating the girder combined with cooling the trunnion-hub in dry-ice/alcohol mixture (AP3-B) is recommended but for hubs with high radial thickness, multistage cooling of the trunnion-hub assembly in dry-ice/alcohol mixture followed by dipping in liquid nitrogen (AP1- multistage cooling) is recommended.
Keywords: Assembly, bridge design, bridge assembly, bascule bridge, stress analysis, design of experiments, fracture, finite element analysis, shrink-fitting, heating, heating coils, steel fulcra, steel fulcrum
DOI: 10.3233/BRS-120046
Journal: Bridge Structures, vol. 8, no. 3-4, pp. 121-133, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]