Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Case Report
Authors: Nakata, Bunzoa; * | Kuroda, Kenjia | Yoshida, Yasuhikob | Iimori, Nozomia | Masuda, Goa | Lee, Tomihiroa | Tendo, Masashigea | Hori, Takeshia | Sato, Hiroshic | Ishikawa, Tetsuroa
Affiliations: [a] Department of Surgery, Kashiwara City Municipal Hospital, 1-7-9 Hozenji, Kashiwara City, Osaka 582-0005, Japan | [b] Department of Dermatology, Kashiwara City Municipal Hospital, 1-7-9 Hozenji, Kashiwara City, Osaka 582-0005, Japan | [c] Department of Internal Medicine, Kashiwara City Municipal Hospital, 1-7-9 Hozenji, Kashiwara City, Osaka 582-0005, Japan
Correspondence: [*] Corresponding author: B. Nakata, Department of Surgery, Kashiwara City Municipal Hospital, 1-7-9 Hozenji, Kashiwara City, Osaka 582-0005, Japan. Tel.: 81-72-972-0885, Fax: 81-72-972-2120. E-mail: [email protected]
Abstract: Here we report the case of a 77-year-old woman with a huge cancer of the right breast for which size was measured on computed tomography in our hospital preoperatively and in other hospital 3 years earlier. During the 3-year untreated interval, the tumor grew from 4 cm to 13 cm in maximum diameter, and the tumor-volume doubling time (TVDT) was calculated as 209 days. The patient underwent mastectomy with axillary lymph node dissection, with the large skin defect covered by autologous skin graft. The pathological diagnosis was pure mucinous carcinoma (MC) of the breast with a low MIB-1 index, no vessel invasion, and no lymph node metastasis. Breast MC has been known to show a slow growth rate, but the TVDT of this current tumor was not markedly different from that of common breast cancers described in previous reports. This short TVDT notwithstanding the low aggressiveness may be due to abundant mucin occupying the majority of the tumor volume. To the best of our knowledge, no previous reports have provided accurate TVDTs for breast MC.
Keywords: Pure mucinous carcinoma, breast cancer, computed tomography
DOI: 10.3233/BD-170300
Journal: Breast Disease, vol. 37, no. 4, pp. 215-218, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]