Abstract: In this study, we present our findings from examining a gas lift tower for produced and tap water de-oxygenation, applying the nitrogen purging at an ultra-fine bubble scale (18 μm average size). The experiments were conducted for produced water samples grafted with polyacrylamide concentration 300 ppm with a measured bulk viscosity of 5 mPa.s. Upon applying a series of experimental sets, 0 ppm DO was attained in all examined operational schemes (semi batch and once through) within various time limits, depending on the water level in the column. Considering the zero DO level as an objective function, the results showed an improvement of 5.7–14 folds in reaching the 0 ppm DO upon experimenting with the ultra-fine bubble purging in different schemes, compared with of the results obtained from the ordinary bubble size (mm scale). The results show that DO reached < 10 ppb within 23 minutes with nitrogen flowrate 3 L/min while DO reaching < 10 ppb within 28 minutes with nitrogen flowrate 5 L/min. Furthermore, implementing the ultra-fine bubble nitrogen purging was successful in running the de-oxygenation tower in a full continuous mode at a balanced inlet/outlet water flow rate. This has been done after reaching stability in the column operation (lasting around 1 hour for 422 L of examined water sample). The stable fine bubbles cloud in the column was quite efficient in treating water influent stream to be exited directly at 0 ppm DO within the same effluent flow rate. The treatment efficiency has shown an increase with increasing water level in the column, resulting in a denser layer/cloud of fine bubbles. This result suggests a unique approach/solution for the complete removal of DO from produced water, which is accounted effective to be adopted industrially
Keywords: Produced water treatment, dissolved oxygen, N2 purging, ultra-fine bubbles
DOI: 10.3233/AJW230077
Journal: Asian Journal of Water, Environment and Pollution, vol. 20, no. 6, pp. 37-43, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]