Article type: Research Article
Authors: Chen, Huei-Yung | Lu, Nan-Han | Huang, Yung-Hui | Chen, Tai-Been
Affiliations: Department of Nuclear Medicine, E-DA Hospital, I-Shou University, Kaohsiung City, Taiwan | Department of Radiology, E-DA Hospital, I-Shou University, Kaohsiung City, Taiwan | Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung City, Taiwan
Note: [] Corresponding author: Tai-Been Chen, Department of Medical Imaging and Radiological Sciences, I-Shou University, No. 8, Yida Rd., Jiaosu Village, Yanchao District, Kaohsiung City 82445, Taiwan. Tel.: +886 7 615 1100 ext. 7802; Fax: +886 7 615 5150; E-mail: [email protected]
Abstract: Positron emission tomography (PET) had been utilized to image gene therapy, estimate tumor growth, detect neural function of the brain, and diagnose disease. However, sinogram noise always results inaccurate PET images. The factorial design of experiment (DOE), a statistical method, was applied to investigate, correct and estimate the fraction of scattering of 2D sinogram in PET. The DOE was included as factors of angle views and scatter media with two levels designed. The PET sinogram after scattering correction was then reconstructed by filtered back projection (FBP). Both Ge-68 uniform phantom and Jaszczak anthropomorphic torso phantom were applied to exam the performance of presented scattering correction algorithm. The signal-to-noise ratio (SNR), standard deviation (STD) of background, and full width at half maximum (FWHM), and uniformity test were applied to validate the performance of presented method. The proposed method provides a narrower FWHM, smaller STD of the background, higher SNR and better uniformity than those of original protocols. This method should be tested for accuracy and feasibility with three-dimensional phantoms or real animal studies and consideration effects of cross-talk between slices in future work.
Keywords: Factorial design of experiment, PET, scattering correction algorithm
DOI: 10.3233/XST-150484
Journal: Journal of X-Ray Science and Technology, vol. 23, no. 2, pp. 243-251, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]