Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 185.00Authors: Javakhishvili, I. | Sanikidze, T. | Mardaleishvili, K. | Momtselidze, N. | Urdulashvili, T. | Mantskava, M. | Prantl, L. | Jung, F.
Article Type: Research Article
Abstract: BACKGROUND: The functioning of the thyroid gland is a multi-component process that in some conditions may undergo alterations. The thyroid gland is part of the endocrine system that produces the iodine-containing hormones thyroxine and triiodothyronine. Thyroid hormones, control metabolism and energy, growth processes, maturation of tissues and organs, regulation of blood flow, and, therefore, providing vital functions of the body. The role of thyroid hormones in the regulation of blood flow is determined by the intensity of their production and the quantity in the blood. Presumably, in case of oncological and non-oncological diseases of the thyroid gland, the fluidity of …the blood, which depends on the rheological properties, will be different. OBJECTIVE: Our aim was investigating rheological characteristics for studying of changes of rheology in patients with thyrotoxicosis, with benign tumor pathology of the thyroid gland, with thyroid cancer and finding possible diagnostic markers for differentiating benign and malignant thyroid tumors METHODS: In this regard, we examined, using modern methods accepted in clinical practice, a standard list of recommended diagnostic tests in the group of patients (thyrotoxicosis: n = 25; benign tumor: n = 47), thyroid cancer: n = 35) and control group (n = 15), and with new original methods, parameters that describe the rheological properties of the blood, such as blood rheological index, volume, thickness, surface area of erythrocytes, erythrocyte aggregation index, deformation index, plasma viscosity, hematocrits. RESULTS: Against the background of relative changes in the studied values, it is necessary to pay attention to the fact that erythrocyte aggregation in patients with a benign form and control, as well as in patients with a malignant form and control, differ significantly from each other, in addition, there is a significant difference between aggregation in the group of patients with benign and control aggregation. malignant forms of the disease. It is significant that aggregability differs in patients with thyrotoxicosis and in controls. This indicates that erythrocyte aggregation is particularly informative. The blood rheological index most clearly demonstrated the difference between benign and malignant forms of the disease. Significantly changed compared to control in various forms of thyroid diseases. CONCLUSION: Additional diagnostic markers for differentiating benign and malignant thyroid tumors may be consideredeerythrocyte aggregation index and blood rheological index. Show more
Keywords: Thyroid gland, rheology, oncology
DOI: 10.3233/CH-249102
Citation: Clinical Hemorheology and Microcirculation, vol. Pre-press, no. Pre-press, pp. 1-12, 2024
Authors: Xu, Ya-Dan | Tang, Yang | Zhang, Qi | Zhao, Zheng-Yong | Zhao, Chong-Ke | Fan, Pei-Li | Jin, Yun-Jie | Ji, Zheng-Biao | Han, Hong | Xu, Hui-Xiong | Shi, Yi-Lei | Xu, Ben-Hua | Li, Xiao-Long
Article Type: Research Article
Abstract: BACKGROUND: At present, most articles mainly focused on the diagnosis of thyroid nodules by using artificial intelligence (AI), and there was little research on the detection performance of AI in thyroid nodules. OBJECTIVE: To explore the value of a real-time AI based on computer-aided diagnosis system in the detection of thyroid nodules and to analyze the factors influencing the detection accuracy. METHODS: From June 1, 2022 to December 31, 2023, 224 consecutive patients with 587 thyroid nodules were prospective collected. Based on the detection results determined by two experienced radiologists (both with more than 15 years …experience in thyroid diagnosis), the detection ability of thyroid nodules of radiologists with different experience levels (junior radiologist with 1 year experience and senior radiologist with 5 years experience in thyroid diagnosis) and real-time AI were compared. According to the logistic regression analysis, the factors influencing the real-time AI detection of thyroid nodules were analyzed. RESULTS: The detection rate of thyroid nodules by real-time AI was significantly higher than that of junior radiologist (P = 0.013), but lower than that of senior radiologist (P = 0.001). Multivariate logistic regression analysis showed that nodules size, superior pole, outside (near carotid artery), close to vessel, echogenicity (isoechoic, hyperechoic, mixed-echoic), morphology (not very regular, irregular), margin (unclear), ACR TI-RADS category 4 and 5 were significant independent influencing factors (all P < 0.05). With the combination of real-time AI and radiologists, junior and senior radiologist increased the detection rate to 97.4% (P < 0.001) and 99.1% (P = 0.015) respectively. CONCLUSONS: The real-time AI has good performance in thyroid nodule detection and can be a good auxiliary tool in the clinical work of radiologists. Show more
Keywords: Artificial intelligence, thyroid, nodule, ultrasonography
DOI: 10.3233/CH-242099
Citation: Clinical Hemorheology and Microcirculation, vol. Pre-press, no. Pre-press, pp. 1-14, 2024
Authors: Jung, Ernst Michael | Kaiser, Ulrich | Herr, Wolfgang | Stroszczynski, Christian | Jung, Friedrich
Article Type: Research Article
Abstract: BACKGROUND: The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS: A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS: Of n = 70 (mean value 48,3 years±20,3 years, range 18–84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by …reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS: The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis. Show more
Keywords: Multimodal liver tissue imaging (M-Ref), UMA, HiFR CEUS, SR CEUS, elastography, fat evaluation, viscosity
DOI: 10.3233/CH-249103
Citation: Clinical Hemorheology and Microcirculation, vol. Pre-press, no. Pre-press, pp. 1-11, 2024
Authors: Yan, Wentao | He, Xiuhua | Wang, Guanjun | Hu, Guochao | Cui, Bin
Article Type: Research Article
Abstract: INTRODUCTION: Visceral adipose tissue-derived serine protease inhibitor (vaspin) is an adipokine. It has been reported that decreased serum vaspin levels are significantly associated with stroke severity and prognosis. PURPOSE: This article aims to explore the theoretical feasibility of vaspin supplementation for cerebral ischemia-reperfusion (I/R) injury. METHODS: The I/R mouse models were constructed by the middle cerebral artery occlusion (MCAO) method, and the effects of vaspin on cerebral infarction, neurological function, angiogenesis and endoplasmic reticulum (ER) stress were explored. To verify the mediation of ER stress in the regulation of vaspin, human brain microvascular …endothelial cells (HBMECs) were subjected to ER stress agonist tunicamycin in vitro . The impacts of vaspin and tunicamycin on oxygen glucose deprivation/ recovery (OGD/R)-induced cell viability, apoptosis, and angiogenesis were examined. RESULTS: Vaspin inhibited blood-brain barrier breakdown and infarction occurred in the brain tissue of the I/R mice. Vaspin also enhanced cerebral neovascularization and reduced the apoptosis. Additional tunicamycin increased the apoptosis of HBMECs and inhibited angiogenesis, reversing the protective effect of vaspin on cells. CONCLUSION: Together, this study reveals that vaspin supplementation reduces cerebral infarction and works against neurological dysfunction. It maintains the survival and angiogenesis capacity of HBMECs by inhibiting ER stress. Show more
Keywords: Vaspin, ER stress, I/R injury, OGD/R, microvascular endothelial cell
DOI: 10.3233/CH-232077
Citation: Clinical Hemorheology and Microcirculation, vol. Pre-press, no. Pre-press, pp. 1-11, 2024
Authors: Sun, Hongshuang | Ren, Yunyun
Article Type: Research Article
Abstract: AIM: The aim of this study was to investigate the role of cerebroplacental ratio (CPR) in the final prenatal care for neonatal respiratory diseases and to analyze the risk of relevant factors associated with neonatal respiratory disorders. METHODS: A prospective cohort study of 795 singleton pregnancies was conducted. The pulsatility indices (PI) of the umbilical artery (UA) and the middle cerebral artery (MCA) were measured, and the MCA to UA ratio (CPR) was determined. The severity of the case is determined by whether or not the newborn has respiratory problems. Compare the CPR correlation between the two groups …and examine the illness prediction factors through a binary logistic regression method. RESULTS: Of the 801 participants, 114 had neonatal respiratory disorders. The mean values of CPR between neonatal respiratory diseases group and control group were 1.78±0.6, 1.97±0.9, respectively (P < 0.001). Maternal age, abortion history, cesarean section history, placental thickness, placental maturity, and amniotic fluid index (AFI) were determined to have no significant link between the two groups after comparison analysis (P > 0.05). It could be found that compared with the control group, CPR MoM indicators of neonatal respiratory distress syndrome, neonatal pneumonia and wet lung disease all show significant decreases. In binary logistic regression analysis, among the variables included in the model, CPR (OR:2.90, P = 0.015), fetal heart monitoring (OR:5.26, P < 0.001), delivery mode (OR:2.86, P < 0.001) and gestational age of delivery (OR:0.92, P < 0.001) were statistically significant in both groups. CONCLUSION: The findings of this study showed that infant respiratory problems were substantially related to CPR value. The correlation indicates that CPR was a powerful reference marker for respiratory disorders. Show more
Keywords: Cerebroplacental doppler ratio, fetal brain sparing, fetal lung maturation, neonatal respiratory disorders
DOI: 10.3233/CH-211333
Citation: Clinical Hemorheology and Microcirculation, vol. Pre-press, no. Pre-press, pp. 1-9, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]