Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sayeed, Taufiquea; * | Samà, Albertb | Català, Andreub | Rodríguez-Molinero, Alejandroc | Cabestany, Joana
Affiliations: [a] Technical Research Centre for Dependency Care and Autonomous Living, Rambla de l'Exposicio, Vilanova i la Geltru, Spain | [b] School of Engineering and Informatics of National University Ireland Galway, Galway, Ireland | [c] Clinical Research Unit, Consorci Sanitari del Garraf, Vilanova i la Geltrú, Spain
Correspondence: [*] Corresponding author: Taufique Sayeed, Interactive Sysetms, E.2.80, Main Building, South Wing, Second Floor, Alpen-Adria Universität Klagenfurt, Universitätsstraße 65-67, 9020 Klagenfurt, Austria. Tel.: +34 93 896 72 76; E-mail: [email protected].
Abstract: Background:Parkinson's disease (PD) is a neurodegenerative disease that predominantly alters patients' motor performance. Reduced step length and inability of step are important symptoms associated with PD. Assessing patients' motor state monitoring step length helps to detect periods in which patients suffer lack of medication effect. Objective:Evaluate the adaption of existing step length estimation methods based on accelerometer sensors to a new position on left lateral side of waist in 28 PD patients. Methods:In this paper, a user-friendly position, the lateral side of the waist, is selected to place a tri-axial accelerometer. A newly developed step detection algorithm – Sliding Window Averaging Technique (SWAT) is evaluated in detecting steps using signals from this location. The detected steps are then used to estimate step length using four proposed correction factors for Zijlstra's, Gonzalez's and Weinberg's methods that were originally developed for the signals from lower back. Result:Results obtained from 28 PD patients are discussed and the effects of calibrating in each motor state are compared. A generic correction factor is also proposed and compared with the best method to use instead of individual calibration. Despite variable gait speed and different motor state, SWAT achieved overall accuracy of 96.76% in step detection. Among the different step length estimators, the Zijlstra method performs better with multiplying individual correction factors that consider left and right step length separately providing average error of 0.033 m. Conclusions:Zijlstra's method with individual correction factor that considers left and right step length separately and obtained from during ON state of a PD patients provide most accurate estimation among the others. As training session is during ON state, data from induced OFF state to train the methods are not required. A generic correction factor is also proposed to apply with Zijlstra's method to avoid individual calibration process.
Keywords: Parkinson's disease, gait properties, accelerometers, signal processing
DOI: 10.3233/THC-140882
Journal: Technology and Health Care, vol. 23, no. 2, pp. 179-194, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]