Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Xu, Bingqiang | Zhong, Hua | Duan, Shaoyin*
Affiliations: Medical Imaging Department, Zhongshan Hospital of Xiamen University, Xiamen, Fujian, China
Correspondence: [*] Corresponding author: Shaoyin Duan, 209 South Hubin Road, Xiamen 361004, Fujian, China. Tel.: +86 592 2993385; Fax: +86 592 2212328; [email protected]
Abstract: BACKGROUND: The rupture of aneurysm is quite common in the clinics, and is hazardous to patients. Its occurrence is considered to be related to the hemodynamic abnormalities. OBJECTIVE: To construct the model of internal carotid artery aneurysm (ICA-A), and have a simulation of blood flow. METHODS: Based on the CTA data from spiral CT scan, the ICA-A model was constructed, and the types of blood flow, wall shear stress (WSS), Von Mises stress (VMS) and pressure were simulated and calculated. RESULTS: ICA-A model has been built and shape is the same morphology as CT 3D-image. In the whole cardiac cycle, the blood flow of aneurysm body is swirl, its velocity is slower than that of aneurysm neck; the maximum deformation, wall shear stress, pressure and von mises stress of aneurysm wall is at the neck, the minimum is at the top. The highest value appeared at 0.52 s in the cardiac cycle of 0.74 s, the lowest is at 0.21 s. CONCLUSIONS: It is effective and practical to construct the model of ICA-A base on CTA data. Blood flow simulation of ICA-A will provide new basis for the study on the occurrence and development of aneurysm.
Keywords: Internal carotid artery, aneurysm, finite element modeling, blood flow simulation
DOI: 10.3233/thc-150927
Journal: Technology and Health Care, vol. 23, no. s1, pp. S43-S48, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]