Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Chen, C.-C.a | Chen, S.-C.b | Shih, Y.-Y.c | Chen, Y.-L.d; *
Affiliations: [a] Department of Management Information Systems, Hwa Hsia University of Technology, New Taipei City, Taiwan | [b] Department of Physical Medical & Rehabilitation, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan | [c] Department of Physical Medical & Rehabilitation, Tao-Yuan Ghang-Gung Memorial Hospital, Taiwan | [d] Department of Digital Technology Design, National Taipei University of Education, Taipei, Taiwan
Correspondence: [*] Corresponding author: Y.-L. Chen, Department of Digital Technology Design, National Taipei University of Education, Taipei, Taiwan. E-mail:[email protected]
Abstract: BACKGROUND: Needle-stick injuries accounts for a great proportion of all medical accidents in developing and undeveloped countries. The main cause of needle-stick accident injuries is the medical personnel's ``recovering'' the needle action after injection. OBJECTIVE: This study applies an electronic technique to the needling instrument for the purpose of automatically detaching the needle. The proposed method can effectively avoid needle-stick accident injury when ``recovering'' the needle. METHODS: The syringe needle auto-detaching device includes an abutment on which there is a turntable mechanism composed of a pedestal, a turn-table and a driving unit. A photo interrupter on the pedestal detects the rotational angle of the turntable and controls the stepping motor through a control circuit. An optical sensor is located on the upper end of the sensing mechanism. When the syringe is inserted into the syringe plughole the exposed portion of the needle will be detected by the optical sensor. After the syringe is placed into the plughole, its needle will be detected by the sensor. At this time the needle will be detached from the syringe and automatically fall down into the needle collection box. RESULTS: The syringe needle auto-detaching device was fatigue tested for an extensive period of time (A group: 1000 times/day for 3 ml, B group: 1000 times/day for 5 ml, C group: 1000 times/day for 3 ml and 5 ml staggered, D group: 1000 times/day for 3 ml and 5 ml randomized). The needle and syringe detachment rates were 100% in all test groups. CONCLUSIONS: The syringe needle auto-detaching device developed in this study, in that the clinician performs only one step to dispose a needle. Six syringe needle sets can be managed sequence second by second. The proposed device without all of the risk factors of the traditional syringe needle detachment device.
Keywords: Needle-stick, medical treatment, needling instrument, needle recovering
DOI: 10.3233/THC-150908
Journal: Technology and Health Care, vol. 23, no. 4, pp. 523-528, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]