Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Tomasevic, Smiljanaa; b | Anic, Milosa; b | Arsic, Brankoa; c | Gakovic, Brankod | Filipovic, Nenada; b | Djukic, Tijanaa; e; *
Affiliations: [a] Bioengineering Research and Development Center, BioIRC, Kragujevac, Serbia | [b] Faculty of Engineering, University of Kragujevac, Kragujevac, Serbia | [c] Faculty of Science, University of Kragujevac, Kragujevac, Serbia | [d] Clinic for Vascular and Endovascular Surgery, Serbian Clinical Centre, Belgrade, Serbia | [e] Institute for Information Technologies, University of Kragujevac, Kragujevac, Serbia
Correspondence: [*] Corresponding author: Tijana Djukic, Institute of Information Technologies, University of Kragujevac, Jovana Cvijica bb, 34000 Kragujevac, Serbia. Tel.: +381 34301920; E-mail: [email protected]. ORCID: 0000-0002-9913-6527.
Abstract: BACKGROUND: Ultrasound is one of the non-invasive techniques that are used in clinical diagnostics of carotid artery disease. OBJECTIVE: This paper presents software methodology that can be used in combination with this imaging technique to provide additional information about the state of patient-specific artery. METHODS: Overall three modules are combined within the proposed methodology. A clinical dataset is used within the deep learning module to extract the contours of the carotid artery. This data is then used within the second module to perform the three-dimensional reconstruction of the geometry of the carotid bifurcation and ultimately this geometry is used within the third module, where the hemodynamic analysis is performed. The obtained distributions of hemodynamic quantities enable a more detailed analysis of the blood flow and state of the arterial wall and could be useful to predict further progress of present abnormalities in the carotid bifurcation. RESULTS: The performance of the deep learning module was demonstrated through the high values of relevant common classification metric parameters. Also, the accuracy of the proposed methodology was shown through the validation of results for the reconstructed parameters against the clinically measured values. CONCLUSION: The presented methodology could be used in combination with standard clinical ultrasound examination to quickly provide additional quantitative and qualitative information about the state of the patient’s carotid bifurcation and thus ensure a treatment that is more adapted to the specific patient.
Keywords: Convolutional neural networks, 3D reconstruction, blood flow, patient-specific geometry, validation against clinical data
DOI: 10.3233/THC-231306
Journal: Technology and Health Care, vol. 32, no. 4, pp. 2553-2574, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]