Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Section: Future Arthroplasty
Guest editors: Mustafa Citak
Article type: Research Article
Authors: Rossi, Stefano Marco Paoloa; * | Sangaletti, Rudya | Andriollo, Lucab | Matascioli, Lucab | Benazzo, Francescoa; c
Affiliations: [a] Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, UOC Ortopedia e Traumatologia, Fondazione Poliambulanza, Brescia, Italy | [b] UOC Ortopedia e Traumatologia Fondazione Poliambulanza, Brescia, Italy | [c] Istituto Universitario di Studi Superiori (IUSS), Pavia, Italy
Correspondence: [*] Corresponding author: Stefano Marco Paolo Rossi, Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, UOC Ortopedia e Traumatologia, Fondazione Poliambulanza Via Bissolati 57, Brescia 25124, Italy. E-mail: [email protected].
Abstract: BACKGROUND: Robotic-assisted total knee arthroplasty (TKA) have shown promising results in recent years with improved clinical outcomes using standard primary implants. OBJECTIVE: The purpose of this study was to assess the experience of a single center in correcting severe coronal deformities with the use of a robotic-assisted TKA system and an increased constrained implant. METHODS: Between July 2020 and December 2022, 30 knees in 28 patients with a major deformity and an associated ligament laxity requiring an increased constrained implant treated using an imageless robotic-assisted TKA were prospectively enrolled. Patients included in the study showed a minimum 15 degrees varus or 10 degrees valgus deviation. RESULTS: 20 cases were varus knees and 10 cases were valgus knees. Postoperative neutral alignment was defined as 0∘± 2.5∘. A CCK implant was used in 20 cases while a Constrained Posterior Stabilized implant was used in 10 cases. A neutral alignment was achieved in all patients. At a minimum 6 months follow up (f-u 6–30 months) clinical outcomes including ROM, KSS, HSS, OKS and WOMAC showed significant improvement and no major complications were registered. CONCLUSIONS: The robotic system showed the achievement of a mechanical alignment with reliable radiographic outcomes and clinical results in the treatment of major deformities of the lower limb with the use of higher constrained implants at short term follow up. Further follow up and studies are necessary to confirm and verify these promising outcomes.
Keywords: Robotics, knee, major deformities, varus, valgus, constaint, computer-aided surgical planning, orthopedic surgery
DOI: 10.3233/THC-231261
Journal: Technology and Health Care, vol. 32, no. 5, pp. 3737-3746, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]