Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chang, Jihuia | Zhang, Shuanga; b | Qiu, XuZhonga | Huang, HaiJuna | Zhang, Yuna | Li, Kaia; *
Affiliations: [a] Department of Orthopaedics, People’s Hospital of Zhongjiang County, Zhongjiang, Sichuan, China | [b] Neijiang City Engineering Technology Research Center of Neurological Disease Information Interference, Neijiang, Sichuan, China
Correspondence: [*] Corresponding author: Kai Li, Department of Orthopaedics, People’s Hospital of Zhongjiang County, Zhongjiang, Sichuan, China. E-mail: [email protected].
Abstract: BACKGROUND: Humeral fracture is a common long bone fracture in orthopedic clinical diagnosis and treatment. OBJECTIVE: To investigate the local temperature increase owing to changes in the specific absorption ratio (SAR) of the human body caused by humeral bone nails during magnetic resonance imaging (MRI). METHODS: A refined geometric model of the upper body was constructed via data segmentation and post-processing using the digital human image dataset. Finally, the geometric model was imported into COMSOL, a 3-T magnetic resonance coil was built, and the operating frequency (128 MHz) was set to analyze the SAR of the bone-nail pair and temperature changes. RESULTS: The analysis of the changes after bone-nail implantation under different tissue conditions revealed that the SAR and temperature after implantation and fixation were three times higher than those before, and the areas with abrupt changes in SAR and temperature were primarily concentrated in the bone-nail area. CONCLUSION: In MRI, metal implants can cause local elevation of the SAR near the implant in the human body, resulting in a temperature increase around the implant. Consequently, long-term scanning can damage the human body.
Keywords: Bone nails, magnetic resonance imaging, temperature rise effect, specific absorption ratio, digital human
DOI: 10.3233/THC-230995
Journal: Technology and Health Care, vol. 32, no. 3, pp. 1897-1907, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]