Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lian, Weizhen1 | Lian, Kaimei1 | Lin, Teng*
Affiliations: Department of Ultrasound, The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong, China
Correspondence: [*] Corresponding author: Teng Lin, Department of Ultrasound, The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong, China. E-mail: [email protected].
Note: [1] These authors contributed equally to this work.
Abstract: BACKGROUND: Early breast cancer diagnosis is of great clinical importance for selecting treatment options, improving prognosis, and enhancing the quality of patients’ survival. OBJECTIVE: We investigated the value of virtual touch tissue imaging average grayscale values (VAGV) helper Breast Imaging Reporting and Data System (BI-RADS) in diagnosing breast malignancy. METHODS: We retrospectively analyzed 141 breast tumors in 134 patients. All breast lesions were diagnosed pathologically by biopsy or surgical excision. All patients first underwent conventional ultrasound (US) followed by virtual touch tissue imaging (VTI). The measurement of the VAGV of the lesion was performed by Image J software. BI-RADS classification was performed for each lesion according to the US. We performed a two-by-two comparison of the diagnostic values of VAGV, BI-RADS, and BI-RADS+VAGV. RESULTS: VAGV was lower in malignant tumors than in benign ones (35.82 ± 13.39 versus 73.58 ± 42.69, P< 0.001). The area under the receiver operating characteristic curve (AUC) value, sensitivity, and specificity of VAGV was 0.834, 84.09%, and 69.07%, respectively. Among BI-RADS, VAGV, and BI-RADS+VAGV, BI-RADS+VAGV had the highest AUC (0.926 versus 0.882, P= 0.0066; 0.926 versus 0.834, P= 0.0012). There was perfect agreement between the two radiologists using VAGV (ICC= 0.9796) and substantial agreement using BI-RADS (Kappa= 0.725). CONCLUSION: Our study shows that VAGV can accurately diagnose breast cancer. VAGV effectively improves the diagnostic performance of BI-RADS.
Keywords: Breast lesion, average grayscale value, virtual touch tissue imaging, Breast Imaging Reporting and Data System
DOI: 10.3233/THC-230306
Journal: Technology and Health Care, vol. 32, no. 2, pp. 925-936, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]