Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Nan, Chonga; 1 | Li, Yanjuna; 1 | Liu, Yuxiub | Ma, Lianga | Ma, Zhanbeia; *
Affiliations: [a] Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China | [b] Department of Neurosurgery, Baoding No.1 Central Hospital, Baoding, Hebei, China
Correspondence: [*] Corresponding author: Zhanbei Ma, Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China. E-mail: [email protected].
Note: [1] Chong Nan and Yanjun Li are authors contributed equally to this work and should be considered co-first authors.
Abstract: BACKGROUND: The femoral neck system (FNS) has been considered as a novel strategy for femoral neck fracture. The diversity of internal fixation creates difficulties in choosing an effective option for Pauwels III type femoral neck fractures. Therefore, it is significant to investigate the biomechanical effects of FNS versus conventional approaches on bones. OBJECTIVE: To evaluate the biomechanical characteristics of FNS versus cannulated screws coupled with medial plate (CSS+MP) for the treatment of Pauwels III type femoral neck fractures. METHODS: Through three-dimensional computer software (Minics, Geomagic – Warp), the proximal femur model was rebuilt. Based on the present clinical characteristics, models of internal fixation were reconstructed in SolidWorks, including cannulated screws (CSS), medial plate (MP) and FNS. After parameter setting and meshing, boundary conditions and loads were set up for the final mechanical calculation in Ansys Software. Under identical experimental conditions, such as the same Pauwels angle and force loading, the peak values of displacement, shear stress and equivalent (von Mises) stress were recorded. RESULTS: This study showed that the displacement of the models was CSS, CSS+MP, and FNS in descending order of magnitude. The shear stress and equivalent stress of the models was CSS+MP, FNS, and CSS in descending order. The principal shear stress of CSS+MP was concentrated on the medial plate. The equivalent stress of FNS was more dispersed and distributed from the proximal main nail to the distal locking screw. CONCLUSION: CSS+MP and FNS exhibited better initial stability compared to CSS. However, the MP was subjected to more shear stress, which could increase the risk of internal fixation failure. Due to its unique design, FNS may be a good choice for the treatment of Pauwels III type femoral neck fractures.
Keywords: Femoral neck system, femoral neck fractures, finite element analysis, biomechanics
DOI: 10.3233/THC-220267
Journal: Technology and Health Care, vol. 31, no. 4, pp. 1161-1170, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]