Article type: Research Article
Authors: Zhang, Lianga | Liu, Benyuanb | Ji, Zhenyub; *
Affiliations: [a] Basic Medical Science Academy, Air Force Military Medical University, Xi’an, Shaanxi, China | [b] Military Biomedical Engineering School, Air Force Military Medical University, Xi’an, Shaanxi, China
Correspondence: [*] Corresponding author: Zhenyu Ji, Military Biomedical Engineering School, Air Force Military Medical University, Xi’an, Shaanxi 710032, China. E-mail: [email protected].
Abstract: BACKGROUND: The dielectric properties of tissues are very important physical factors for the investigation and application of bio-electromagnetism. However, the size of the active sample tissue is usually limited in actual measurement, making it difficult to meet the requirements of the existing high-frequency measurement methods, thus influencing the measurement results. OBJECTIVE: The present study aimed to systematically investigate the various factors influencing the effective measurement area of the open-ended coaxial probe, including the design size of the probe and the dielectric properties of the object to be measured. METHODS: The simplified material mixing model, in which several types of materials were set as the material under test (MUT) and the perfect conductor (PEC) was set as the specific material, was used in the simulation to study the effective measurement area of eight types of probes with different sizes for the dielectric measurement of different MUTs. Different concentrations of NaCl solutions and three types of coaxial probes were used in the actual measurement to verify the simulation results. RESULTS: According to the simulation results, the effective measurement area, especially the effective measurement radius, was closely related to the outer conductor radius of the probe. The effective measurement area of the probe decreased when the outer conductor radius of the probe reduced. Moreover, the change in the effective measurement area of the probe was independent of the MUT when the cross-sectional size of the probe was smaller than a certain threshold value. The experimental results also confirmed this conclusion. CONCLUSION: According to the research results, the independent variable dimension could be effectively reduced and the modeling difficulty was reduced when the analysis model of the effective measurement area of the probe was established.
Keywords: Dielectric measurement, effective measurement area, coaxial probe, bioelectromagnetism, biological tissues
DOI: 10.3233/THC-220192
Journal: Technology and Health Care, vol. 31, no. 2, pp. 621-633, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]