Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Temporiti, Federicoa; b | Adamo, Paolaa | Mandelli, Andreab | Buccolini, Fabioc | Viola, Erikac | Aguzzi, Damianoc | Gatti, Robertoa; b; * | Barajon, Isabellab
Affiliations: [a] Physiotherapy Unit, Humanitas Clinical and Research Center – IRCCS, Milan, Italy | [b] Department of Biomedical Sciences, Humanitas University, Milan, Italy | [c] BHOHB S.r.l., Rome, Italy
Correspondence: [*] Corresponding author: Roberto Gatti, Physiotherapy Unit, Humanitas Clinical and Research Center and Humanitas University, Via Manzoni 56, Rozzano, Milan, Italy. E-mail: [email protected].
Abstract: BACKGROUND: The BHOHB system (Bhohb S.r.l., Italy) is a portable non-invasive photographic marker-based device for postural examination. OBJECTIVE: To assess the test-retest reliability of the BHOHB system and compare its reliability with an optoelectronic system (SMART-DX 700, BTS, Italy). METHODS: Thirty volunteers were instructed to stand upright with five markers on the spinous processes of C7, T6, T12, L3 and S1 vertebrae to define the dorsal kyphosis and lumbar lordosis (sagittal plane) angles. Three markers were placed on the great trochanter, apex of iliac crest and lateral condyle of the femur to detect pelvic tilt. Finally, to define angles between the acromion and the spinous processes (frontal plane), two markers were placed on the right and left acromion. Postural angles were recoded simultaneously with BHOHB and optoelectronic systems during two consecutive recording sessions. RESULTS: The BHOHB system revealed excellent reliability for all the angles (ICCs: 0.92–0.99, SEM: 0.78∘–3.33∘) as well as a shorter processing time compared to the optoelectronic system. Excellent reliability was also found for all the angles detected through the optoelectronic system (ICCs: 0.91–0.99, SEM: 0.84∘–2.80∘). CONCLUSION: The BHOHB system resulted as a reliable non-invasive and user-friendly device to monitor spinal posture, especially in subjects requiring repeat examinations.
Keywords: Posture, postural assessment, photographic system, optoelectronic system
DOI: 10.3233/THC-220155
Journal: Technology and Health Care, vol. 31, no. 4, pp. 1153-1160, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]