Authors: He, Dong-Cheng | Zhu, Zhi-Jian | Zhang, Xiao-Ye | Zhang, Yan | Hong, Jun | Shi, Ting-Ting | Han, Ji-Hua*
Affiliations: Department of Radiation Oncology, The Affiliated Huaian No. 1 People’s Hospital of Nanjing Medical University, Huai’an, Jiangsu, China
Correspondence: [*] Corresponding author: Ji-Hua Han, Department of Radiation Oncology, The Affiliated Huaian No. 1 People’s Hospital of Nanjing Medical University, 1 Huanghe Road West, Huaiyin District, Huai’an City, Jiangsu 223300, China. E-mail: [email protected].
Abstract: BACKGROUND: Cervical cancer is a common gynecological cancer among women worldwide. OBJECTIVE: To determine the effects of 6 MV and 10 MV volumetric-modulated arc therapy (VMAT) photon beams on the target volume (TV) planning and critical organs in cases of cervical cancer. METHODS: Fifty patients with carcinoma of the cervix who underwent radiotherapy were selected. The transverse diameter (T) of the cross section of the upper edge of the sacroiliac joint on computerized tomography (CT) images of the patients was measured, and the mean value was calculated as 34 cm. All patients were divided into two groups: Group A (T < 34 cm) and Group B (T > 34 cm). The VMAT plans were generated using 6 MV and 10 MV plans separately. The prescription dose was 47.5 Gy, and the daily dose was 1.9 Gy. RESULTS: In Group A, the planning target volume (PTV) dose assessment parameters of 6 MV and 10 MV plans and their homogeneity and conformity indices were not statistically significantly different. A significant difference was observed between the 6 MV and 10 MV plans for the PTV dose assessment parameters and the homogeneity index of the plans for Group B. The monitor units (MUs) of the 10 MV plans were lower than in the 6 MV plans in both Groups A and B, and the difference was statistically significant. The assessment parameter V40 Gy of both the rectum and bladder in the 6 MV plans was smaller than the corresponding parameter in the 10 MV plans in Group A; in Group B, the assessment parameter V50 Gy of the rectum in the 10 MV plans was smaller than in the 6 MV plans. CONCLUSION: When T < 34 cm, 6 MV energy is more suitable for the external irradiation of cervical cancer. When T > 34 cm, 10 MV energy is more suitable for cervical cancer radiotherapy. Therefore, 10 MV should be considered for patients with a large abdominal size.
Keywords: Volumetric-modulated arc therapy, cervical cancer, transverse diameter, 6 MV, 10 MV
DOI: 10.3233/THC-213617
Journal: Technology and Health Care, vol. 30, no. 6, pp. 1515-1523, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]