Affiliations: [a] Guangdong Provincial Key Lab of Robotics and Intelligent System, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China | [b] CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China | [c] Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China
Correspondence: [*] Corresponding author: Xinyu Wu, Guangdong Provincial Key Lab of Robotics and Intelligent System, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China. E-mail: %****␣thc-30-thc213177_temp.tex␣Line␣125␣****[email protected].
Note: [1] These authors contributed equally to this work.
Abstract: BACKGROUND: The exoskeleton for lower limb rehabilitation is an uprising field of robot technology. However, since it is difficult to achieve all the optimal design values at the same time, each lower extremity exoskeleton has its own focus. OBJECTIVE: This study aims to develop a modular lightweight lower extremity exoskeleton (MOLLEE) with novel compliant ankle joints, and evaluate the movement performance through kinematics analysis. METHODS: The overall structure of the exoskeleton was proposed and the adjustable frames, active joint modules, and compliant ankle joints were designed. The forward and inverse kinematics models were established based on the geometric method. The theoretical models were validated by numerical simulations in ADAMS, and the kinematic performance was demonstrated through walking experiments. RESULTS: The proposed lower extremity offers six degrees of freedom (DoF). The exoskeleton frame was designed adjustable to fit wearers with a height between 1.55 m and 1.80 m, and waist width from 37 cm to 45 cm. The joint modules can provide maximum torque at 107 Nm for adequate knee and hip joint motion forces. The compliant ankle can bear large flexible deformation, and the relationship between its angular deformation and the contact force can be fitted with a quadratic polynomial function. The kinematics models were established and verified through numerical simulations, and the walking experiments in different action states have shown the expected kinematic characteristics of the designed exoskeleton. CONCLUSIONS: The proposed MOLLEE exoskeleton is adjustable, modular, and compliant. The designed adjustable frame and compliant ankle can ensure comfort and safety for different wearers. In addition, the kinematics characteristics of the exoskeleton can meet the needs of daily rehabilitation activities.
Keywords: Lower extremity exoskeleton, walking rehabilitation, lightweight structure, modular design, compliant joint, kinematics analysis
DOI: 10.3233/THC-213177
Journal: Technology and Health Care, vol. 30, no. 4, pp. 881-894, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]