Article type: Research Article
Authors: Alfouzan, Afnan F.a; * | Alotiabi, Hadeel M.b | Labban, Nawafa | Al-Otaibi, Hanan N.a | Al Taweel, Sara Mohammada | AlShehri, Huda A.a
Affiliations: [a] Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia | [b] Dental Intern, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia
Correspondence: [*] Corresponding author: Afnan F. Alfouzan, Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, PO Box 89300, Riyadh 11682, Saudi Arabia. E-mail: [email protected].
Abstract: BACKGROUND: The use of 3D printed material in the dental field is gaining tremendous attention. However, studies related to 3D printed denture resins are scarce and need consideration before their inclusion in routine clinical practice. OBJECTIVE: This study aimed to assess the surface roughness (Ra) of 3D printed denture resins following aging and mechanical brushing. METHODS: Forty round samples (diameter, 10 mm and thickness, 3 mm) were fabricated from two 3D printed (DentaBASE and Denture 3D+) and one conventional polymethylmethacrylate (PMMA) denture materials. The samples were thermo-cycled, subjected to mechanical brushing, and later immersed in either artificial saliva (AS), coffee, cola, or lemon juice (n= 10) to simulate one and two years of oral use. Surface roughness (Ra) was determined using a non-contact profilometer and scanning electron microscope was used for qualitative analysis. The data was analyzed using SPSS v.20 (α= 0.05). RESULTS: Denture 3D+ demonstrated highest mean Ra (1.15 ± 0.28 μm), followed by PMMA (0.99 ± 0.50 μm) and DentaBASE (0.81 ± 24). The difference in mean Ra between the materials was statistically non-significant (P= 0.08). Amongst the different beverages used, the highest Ra was observed for samples immersed in lemon juice (1.06 ± 0.40 μm) followed by cola (1.04 ± 0.46 μm) and coffee (0.98 ± 0.40 μm), respectively. The lowest Ra was observed for samples immersed in AS (0.85 ± 0.24 μm). CONCLUSION: The surface roughness of 3D printed denture resins was comparable with that of conventional PMMA resins. Denture 3D+ demonstrated the highest mean roughness, followed by PMMA and DentaBASE.
Keywords: 3D printed dentures, bacterial adherence, mechanical brushing, staining, surface topography
DOI: 10.3233/THC-212974
Journal: Technology and Health Care, vol. 30, no. 1, pp. 161-173, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]