Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Brief Report
Authors: Vagnini, Alessandroa | Furone, Robertaa | Zanotti, Giuliab | Adamo, Paolab | Temporiti, Federicob; c | Gatti, Robertob; c; *
Affiliations: [a] BTS S.p.A., Milan, Italy | [b] Physiotherapy Unit, Humanitas Clinical and Research Center – IRCCS Rozzano, Milan, Italy | [c] Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
Correspondence: [*] Corresponding author: Roberto Gatti, Physiotherapy Unit, Humanitas Clinical and Research Center and Humanitas University, Via Manzoni 56, 20089 Rozzano, Milan, Italy. Tel.: +39 282245610; E-mail: [email protected].
Abstract: BACKGROUND: Optoelectronic systems and force platforms represent the gold standard for postural sway assessment, but pose disadvantages in terms of equipment, cost and preparation time. OBJECTIVE: Wearable inertial measurement units (IMUs) have been proposed to overcome these issues, but have never been compared to an optoelectronic system. The study aim was therefore to investigate agreement between inertial measurement unit and optoelectronic system in postural sway assessment. METHODS: Thirty healthy volunteers performed four balance tasks. IMU was placed on the sacrum (S2) with a retroreflective marker over the sensor and subjects’ performance was simultaneously recorded by both systems. Total (TOT), anterior-posterior (AP) and medial-lateral (ML) length of trace, range, speed, root mean squared (RMS), and confidence ellipse were computed. RESULTS: ICCs revealed excellent correlations for Length-TOT, Length-AP and Speed-AP, good correlation for Length-ML, Speed-ML, Confidence Ellipse, Range-AP and RMS-AP, and moderate correlation for range-ML and RMS-ML. Bland-Altman plot showed greater estimation for Length-TOT, Length-AP, Speed-AP, confidence ellipse and RMS-AP using optoelectronic system, and for Length-ML, Range-AP, Range-ML, Speed-ML, RMS-ML using IMU. Both systems revealed the same differences among tasks. CONCLUSION: The excellent to good agreement of IMU for length of trace and speed parameters and its user-friendly application suggest its potential implementations in clinical practice.
Keywords: Optoelectronic system, Inertial Measurement Unit, postural sway
DOI: 10.3233/THC-212924
Journal: Technology and Health Care, vol. 30, no. 3, pp. 757-762, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]