Article type: Other
Authors: Zhang, Yibina; b | Cao, Wujingc | Yu, Hongliua; * | Meng, Qiaolinga | Lv, Jieb
Affiliations: [a] Rehabilitation Engineering and Technology Institute, University of Shanghai for Science and Technology, Shanghai, China | [b] Shanghai University of Medicine and Health Sciences, Shanghai, China | [c] Guangdong Provincial Key Lab of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
Correspondence: [*] Corresponding author: Hongliu Yu, Rehabilitation Engineering and Technology Institute, University of Shanghai for Science and Technology, Shanghai, China. Email: [email protected].
Abstract: BACKGROUND: Gait analysis is important for the lower limb prosthesis design. Simulating the natural motion of the human knee in different terrains is useful for the design and performance assessment of the prosthetic knee. OBJECTIVE: This study aimed to propose a four-bar knee joint measurement system which can simulate the natural knee motions to collect the kinetic parameters precisely and analyze the walking characteristics under different terrain conditions. METHODS: A low-cost four-bar knee joint mechanism was proposed and gait characteristics were assessed on level ground, ascending and descending stairs, and ascending and descending ramp. RESULTS: The initial knee flexion angle during stair ascent at heel strike is obviously larger than in other walking scenes. The stance phase accounts for 53% of a single gait cycle during stair descent, which is slightly lower than other walking scenarios. The period that both the hindfoot and forefoot contact the ground in ramp descent accounts for 18%, which is less than for the others. While the forefoot contacts the ground in ramp ascent, the maximum vertical ground reaction force of the forefoot occurs when the hindfoot and forefoot simultaneously contact the ground, whereas in other scenarios the forefoot contacts the ground solely. CONCLUSIONS: The four-bar knee joint can simulate the natural motion of the human knee accurately. The gait characteristics analysis of different walking scenarios indicated that the low-cost four-bar knee joint exoskeleton was suitable for human knee joint simulation.
Keywords: Gait analysis, knee joint, different terrains, kinetic parameters
DOI: 10.3233/THC-202667
Journal: Technology and Health Care, vol. 29, no. 4, pp. 823-828, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]