Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hua, Zhena | Wang, Jian-Weia | Lu, Zhen-Feia | Ma, Jian-Weib | Yin, Henga; *
Affiliations: [a] Wuxi Hospital Affiliated to Nanjing University of Chinese Medicine, Wuxi, Jiangsu, China | [b] Shanghai Institute of Applied Mathematics and Mechanics, Shanghai, China
Correspondence: [*] Corresponding author: Heng Yin, Wuxi Hospital Affiliated to Nanjing University of Chinese Medicine, Wuxi 214071, Jiangsu, China. Tel.: +86 510 88859999; Fax: +86 510 82721071; E-mail: [email protected].
Abstract: BACKGROUND: The distal radius fracture is one of the common clinical fractures. At present, there are no reports regarding application of the finite element method in studying the mechanism of Colles fracture and the biomechanical behavior when using splint fixation. OBJECTIVE: To explore the mechanism of Colles fracture and the biomechanical behavior when using different fixed splints. METHODS: Based on the CT scanning images of forearm for a young female volunteer, by using model construction technology combined with RPOE and ANSYS software, a 3-D distal radius fracture forearm finite element model with a real shape and bioactive materials is built. The material tests are performed to obtain the mechanical properties of the paper-based splint, the willow splint and the anatomical splint. The numerical results are compared with the experimental results to verify the correctness of the presented model. Based on the verified model, the stress distribution of different tissues are analyzed. Finally, the clinical tests are performed to observe and verify that the anatomical splint is the best fit for human body. RESULTS: Using the three kinds of splints, the transferred bone stress focus on the distal radius and ulna, which is helpful to maintain the stability of fracture. Also the stress is accumulated in the distal radius which may be attributed to flexion position. Such stress distribution may be helpful to maintain the ulnar declination. By comparing the simulation results with the experimental observations, the anatomical splint has the best fitting to the limb, which can effectively avoid the local compression. CONCLUSION: The anatomical splint is the most effective for fixing and curing the fracture. The presented model can provide theoretical basis and technical guide for further investigating mechanism of distal radius fracture and clinical application of anatomical splint.
Keywords: Distal radius fracture, anatomical splint, willow splint, paper-based splint, experiment, finite element model, stress analysis, clinical tests
DOI: 10.3233/THC-171050
Journal: Technology and Health Care, vol. 26, no. 2, pp. 329-341, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]