Article type: Research Article
Authors: Xie, Xinzhou* | Li, Yabing | Xie, Songyun
Affiliations: Department of Electronic Science and Technology, Northwestern Polytechnical University, Xi’an, Shaanxi, China
Correspondence: [*] Corresponding author: Xinzhou Xie, Department of Electronic Science and Technology, Northwestern Polytechnical University, Xi’an, Shaanxi, China. E-mail: [email protected].
Abstract: BACKGROUND:Flow recirculation occurs in eccentric coronary stenosis, which can lead to adverse outcome. The complex local geodesic patterns of eccentric stenosis are critical factors in determining the flow characteristics in post-stenotic flow. OBJECTIVE:The main objective of this study is to relate the relationship between the detailed morphological parameters in eccentric coronary stenosis and the post-stenotic flow characteristics. METHODS:Several idealized eccentric coronary stenosis models with variable morphological parameters are created to conduct a series of computational fluid dynamics analysis. The impact of four specific lesion morphological parameters, eccentricity index (EI), diameter stenosis (DS), stenosis length (SL) and shape of lesion, are investigated. RESULTS:When EI is small (< 0.33), the length of recirculation zones would increase as EI increase; while when EI is large (> 0.33), it would decreased as EI increase; Larger magnitude of retrograde flow occurs in models with smaller EIs. Both the recirculation zone length and maximum shear rate increase significantly as DS increases. Increase of SL will lead to increase of recirculation zone length. Higher maximum shear rate and larger recirculation zone are observed in models with sharper stenosis shape. CONCLUSIONS:Except DS, the detailed geometry patterns (EI, SL and shape of the stenosis) also have great impact on post-stenotic flow behaviors in eccentric coronary stenosis.
Keywords: Eccentric coronary stenosis, computational fluid dynamics analysis, morphological parameters, post-stenotic flow characteristics
DOI: 10.3233/THC-160529
Journal: Technology and Health Care, vol. 26, no. 2, pp. 229-238, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]