Article type: Research Article
Authors: Weinans, Harrie; *
Affiliations: Erasmus Orthopaedic Research Lab., Erasmus University Rotterdam and Department of Orthopaedics, University of Nijmegen, the Netherlands
Correspondence: [*] Address for correspondence: Harrie Weinans, Erasmus Orthopaedic Research Lab., EE 1614, Erasmus University Rotterdam, P.O. Box 1738, 3000 DR Rotterdam, the Netherlands. Tel.: +31 10 4087367; Fax: +31 10 4367118; E-mail: [email protected].
Abstract: The stiffness and strength of cancellous bone depends on the amount of bone mineral (BMD) and on the three-dimensional distribution of the mineral (architecture). The relationship between mechanical properties and architecture, excluding confounding effects due to BMD can be studied using computer models of cancellous bone. It was shown that adaptation to mechanical deformation energy leads to an architecture which is an optimal or semi-optimal configuration with respect to maximal stiffness and minimal mass. Thus, the stiffness of the cancellous bone relative to the amount of bone (the bone density) can be considered as an optimality criterion. Based on these findings we assumed that the status of osteoporosis – or better fracture risk – could be related to how close this optimality criterion was met. In other words, we assumed that a higher fracture risk is simply related to a less optimal structure. This was tested for cancellous bone samples taken from post mortem vertebral bodies from two groups of subjects: one group with high fracture incidence during their lives and one group of “healthy” controls. It was found that the specimen from the high fracture incidence group had an architecture leading to a slightly stiffer structure relative to the BMD value. The conclusion is therefore that vertebral bone specimen from subjects with high fracture incidence are better optimized which was contradictory to what we expected. This finding indicates that bone specimen from the “healthy” control subjects had bone matrix at locations which are relatively unloaded. This tissue can be considered as not mechanically efficient or functional. A possible explanation of the present findings is that bone from subjects with increased fracture incidence is better adapted to mechanical stress, because it needs all bone material to carry the load. This stronger adaptation might be related to a compromised safety factor against bone loss, or diminished intrinsic matrix properties (e.g., microdamage).
Keywords: Osteoporosis, bone architecture, cancellous bone, bone adaptation
DOI: 10.3233/THC-1998-65-603
Journal: Technology and Health Care, vol. 6, no. 5-6, pp. 299-306, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]