Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ambusam, Subramaniama | Omar, Baharudinb | Joseph, Leonarda; * | Meng, Seng Pohc | Padzil, Fazlina Asma Mohda
Affiliations: [a] School of Rehabilitation Sciences, Wellness and Rehabilitation Research Niche Group, Faculty of Health Science, Universiti Kebangsaan Malaysia, Malaysia | [b] Department of Biomedical Sciences, School of Diagnostic and Applied Health Sciences, Wellness and Rehabilitation Research Niche Group, Faculty of Health Science, Universiti Kebangsaan Malaysia, Malaysia | [c] Biofit Technology and Services, Singapore
Correspondence: [*] Corresponding author: Dr Leonard Joseph, Senior Lecturer in Physiotherapy, Program Physiotherapy, School of Rehabilitation Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia. Tel.: +60 19 6781935; E-mail:[email protected]
Abstract: BACKGROUND: The reliability of a triaxial accelerometer in measuring the head excursion during typing task among occupational typists has not been reported so far. OBJECTIVE: This study aimed to investigate the intra-rater reliability of triaxial accelerometer measurement of head excursion. METHODS: The triaxial accelerometer measurements were taken to measure head excursion of 8 participants typing in the computer. The intra-rater reliability such as intraclass correlation coefficient, standard error of measurements and coefficient of variation was calculated. The Bland-Altman plot was performed to strengthen the study result. RESULTS: The analysis of the results showed that the intra-rater reliability of triaxial accelerometer was high with intraclass correlation coefficient (2,1) of 0.986, standard error of measurements (1.05 Hz) and coefficient of variation (3.2%) for two trials of measurements. The Bland-Altman reported an acceptable agreement between the two measurements taken using the triaxial accelerometer to measure head excursion. CONCLUSIONS: The triaxial accelerometer is a simple, objective and useful technology to measure head excursion among the occupational typists.
Keywords: Accelerometer, head excursion, neck movement, reliability, measurement
DOI: 10.3233/THC-151015
Journal: Technology and Health Care, vol. 23, no. 5, pp. 691-697, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]