Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Peng, Yuping | Qiu, Mingxing | Yu, Lei | Fan, Jun | Qi, Songtao* | Li, Yu | Hu, Zheng | Song, Ye
Affiliations: Department of Neurosurgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China
Correspondence: [*] Corresponding author: Songtao Qi, Department of Neurosurgery, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Dadao Bei Street, Guangzhou 510515, Guangdong, China. Tel.: +86 20 6164 1801; Fax: +86 20 6164 1806; E-mail:[email protected]
Abstract: BACKGROUND: The sheath is a crucial piece of equipment during endoscopic third ventriculostomy (ETV). However, the normally used metal sheath can not provide clear images around the tube. OBJECTIVE: We developed a new transparent sheath (TS) in order to overcome the inherent disadvantages of the metal sheath (MS). MATERIAL AND METHODS: Between August 2010 and February 2013, a total of 120 hydrocephalus patients received ETV in our hospital. Patients were retrospectively divided into two groups, the transparent sheath group (TSG) and metal sheath group (MSG). The success rate of the first puncture, the operative time and the incidence of complications were used to compare the efficiency between transparent sheath and metal sheath. RESULTS: There were 32 patients in the TSG and 88 patients in the MSG. The success rate of the first puncture was 100% in the TSG and 87.5% in the MSG, respectively (p= 0.036). The operative time of the TSG was significant shorter than the MSG (p= 0.001). While the incidence of complications was similar between the two groups (p= 0.757). CONCLUSIONS: Compared with the tranditional metal sheath, the newly developed transparent sheath for ETV is more efficient and showed lower risk. This may be explained by the better surgical view of the whole puncture channel provide by the TS.
Keywords: Neuroendoscope, surgical instrument, transparent sheath, hydrocephalus, endoscopic third ventriculostomy, intracranial tumors
DOI: 10.3233/THC-151006
Journal: Technology and Health Care, vol. 23, no. 5, pp. 667-673, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]