Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Schofield, Jonathon S.a | Dawson, Michael R.b | Carey, Jason P.a | Hebert, Jacqueline S.b; c; *
Affiliations: [a] Department of Mechanical Engineering, University of Alberta, Edmonton, Canada | [b] Glenrose Rehabilitation Hospital, Edmonton, Canada | [c] Faculty of Medicine, University of Alberta, Edmonton, Canada
Correspondence: [*] Corresponding author: Jacqueline S. Hebert, Faculty of Medicine, University of Alberta, 5005 Katz Building, Edmonton, Canada. Tel.: +1 780 735 8870; Fax: +1 780 735 6018; E-mail: [email protected].
Abstract: Background:Strategic vibration of musculotendinous regions of a limb elicits illusionary sensations of movement. As a rehabilitation technique, this ‘kinesthetic illusion’ has demonstrated beneficial results for numerous sensory-motor disorders. However, literature shows little consistency in the vibration parameters or body positioning used, and their effects have yet to be comprehensively investigated. Objective:To characterize the effects of the vibration amplitude, frequency, and limb position on the kinesthetic illusion. Methods:Movement illusions were induced in 12 participants’ biceps and triceps. The effect of amplitude (0.1 to 0.5 mm), frequency (70 to 110 Hz), and two limb positions were quantified on the strength of illusion (SOI), range of motion (ROM) and velocity. Results:Amplitude significantly affected the illusionary SOI, ROM and velocity in the biceps and triceps (p < 0.05). Increasing amplitude resulted in an increase of all three output variables. Limb position showed an effect on illusionary velocity in the biceps as well as ROM and velocity in the triceps (p < 0.05). Frequency demonstrated no statistical effect. Conclusions:Amplitude demonstrated the most profound impact on the kinesthetic illusion in the experimental ranges tested. This work may help guide clinicians and researchers in selecting appropriate vibratory parameters and body positions to consistently elicit and manipulate the kinesthetic illusion.
Keywords: Kinesthetic illusion, vibration illusion, movement illusion, factorial design
DOI: 10.3233/THC-140879
Journal: Technology and Health Care, vol. 23, no. 2, pp. 129-141, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]