Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Reising, K.; * | Konstantinidis, L. | Helwig, P. | Wagner, F.C.L. | Südkamp, N.P. | Strohm, P.C.
Affiliations: Department of Surgery, Clinic for Orthopedic and Trauma Surgery, Freiburg University Hospital, Freiberg, Germany
Correspondence: [*] Corresponding author: Kilian Reising, Department of Surgery, Clinic for Orthopedic and Trauma Surgery, Freiburg University Hospital, Hugstetter Str. 55, D-79106 Freiburg, Germany. E-mail: [email protected].
Abstract: Background:Fracture of the distal humerus is a fairly rare injury and makes high demands on the treating surgeon. Prerequisites for a good outcome are anatomical reconstruction and osteosynthesis stable enough for exercises. A method permitting early restoration of function is especially important for patients with osteoporosis. The extensive surgical approach necessary for open reduction is associated with a high number of wound healing disorders and infections with a frequency of 11% being reported in the literature. Although open reduction and internal fixation in double-plating technique is unavoidable for complex intraarticular fractures, an alternative, minimally invasive and, consequently, tissue-preserving procedure is desirable for simpler fractures. Objectve:To investigate this issue further an angular stable nail system developed for the distal radius was implanted as a stabilizer and the construct tested biomechanically as part of a feasibility study. Methods:Distal humerus fractures were stabilized by insertion of a distal radius nail, namely, the Targon DR (Aesculap, Tuttlingen) and a K-wire. To test the hypothesis six cadaveric bones fixed in formalin were tested biomechanically for displacement, implant failure, and stiffness. Displacement was determined by means of an ultrasound-based system. Results:An average displacement of 1.6 mm ± 0.7 was recorded at a maximum compression force of 100 N in extension and an average displacement of 1.4 mm ± 0.9 in flexion. Implant failure was not observed for any of the constructs. Conclusions:The study presented here permits the conclusion that a minimally invasive procedure is possible at the distal humerus and does ensure adequate stability. Although the nail was not specifically designed for the humerus, current findings form the basis for a promising approach that will be pursued further after modification of the nail design.
Keywords: Distal humerus fracture, minimal invasive, nail osteosynthesis, angular stable
DOI: 10.3233/THC-140864
Journal: Technology and Health Care, vol. 22, no. 6, pp. 909-913, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]