Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Joller, Daniela | Mushkolaj, Shpenda | Ratia-Garcia, Javiera | Marti, Floriana | Bachmann, Alexanderb | Müller, Berta; *
Affiliations: [a] Biomaterials Science Center, University of Basel, Basel, Switzerland | [b] Department of Urology, University Hospital Basel, Basel, Switzerland
Correspondence: [*] Address for correspondence: Prof. Bert Müller, Thomas Straumann Chair for Materials Science in Medicine, Biomaterials Science Center, c/o University Hospital Basel, CH-4031 Basel, Switzerland. Tel.: +41 61 265 9660; Fax: +41 61 265 96 99; E-mail: [email protected].
Abstract: The study demonstrates that the minipig urethra is an appropriate animal model for in vitro experiments and therefore promising for long-term animal tests of artificial urinary sphincter systems in vivo. Freshly explanted porcine and minipig urethras were connected to a fluid reservoir that simulated the bladder pressure. This bladder pressure was adjusted by changing the water level (hydrostatic pressure). Specially designed aluminum sphincters loaded with a fluid-filled container were used to close/open the urethras. Results from minipigs and domestic pigs were compared to data published for human urethras. We measured the leak-point pressures (LPP) by adjusting the bladder pressure at a constant sphincter length and by changing the sphincter length at a constant bladder pressure. Because the urethral tissue shows visco-elastic behavior, LPPs for both opening and closing were measured. By fitting the in vitro data, we evaluated the three characteristic parameters from the empirical urethra compression model, i.e. wall pressure (pW), rim force (FR), and rim length (LR). From the experimental data we found agreement of mean values between (male) human urethras: ⟨pW⟩opening=−(12.9±0.9) cmH2O, ⟨pW⟩closing=(8.6±1.1) cmH2O, ⟨FR⟩opening=(0.06±0.02) N, ⟨FR⟩closing=(0.10±0.02) N, ⟨LR⟩opening=(3.0±0.3) mm, ⟨LR⟩closing=(5.1±0.3) mm, and (male) minipig urethras: ⟨pW⟩opening=−(13.4±0.3) cmH2O, ⟨pW⟩closing=−(8.6±0.4) cmH2O, ⟨FR⟩opening=(0.19±0.01) N, ⟨FR⟩closing=(0.21±0.02) N, ⟨LR⟩opening=(2.4±0.1) mm, ⟨LR⟩closing=(3.3±1.0) mm. These in vitro tests quantified by means of the urethra compression model demonstrate that the minipig (especially the male one) represents a suitable animal model for testing artificial urinary sphincters.
Keywords: In vitro testing, animal model, artificial urinary sphincter, minipig urethra, urinary incontinence, urethra compression model
DOI: 10.3233/THC-2012-0675
Journal: Technology and Health Care, vol. 20, no. 4, pp. 329-336, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]