Article type: Research Article
Authors: Bouaicha, Samy; * | Dora, Claudio | Puskas, Gabor J. | Koch, Peter P. | Wirth, Stephan H. | Meyer, Dominik C.
Affiliations: Department of Orthopaedics, Balgrist University Hospital Zurich, Switzerland
Correspondence: [*] Corresponding author: Samy Bouaicha, MD., Divison of Traumatology, University Hospital of Zurich, Raemistrasse 100, CH-8091 Zurich. Tel.: +41 44 255 11 11; Fax: +41 44 255 44 13; E-mail: [email protected].
Abstract: Introduction:Compared to rigid arthroscopic optics, a flexible camera system offers theoretically significant advantages: It has the potential to adapt to the naturally curved surface of joints, to move within the joint without stress to the cartilage or capsule and thereby to reduce the number of portals needed. Former studies evaluated flexible fiberoptic systems which were insufficient regarding image resolution. This is the first report on a new flexible videoendoscope with the so called “chip-on-the-tip” technology used in human joints. Methods:With a plasma sterilized 3.9 diameter flexible video endoscopy system (Visera ENF V, OLYMPUS) commonly used in diagnostic rhino-laryngoscopy, we performed preliminary testing in cadaveric knee joints. After successful feasibility testing we utilized the tool in two qualitative diagnostic knee and five hip arthroscopies in combination with conventional rigid 30° and 70° arthroscopes (STORZ). Results:Qualitative evaluation showed superior visualisation of the posterior aspects of the knee joint as insertion of the posterior medial and lateral meniscal horn, tibial insertion of the posterior cruciate ligament and the posterolateral capsulo-ligamentous corner with acceptable image resolution and clarity compared to the rigid arthroscope. In the hip, it was possible to pass around the femoral neck, avoiding additional portals. There seemed to be virtually no risk for cartilage damage at all. Difficulties of the system were scope handling, navigation and orientation within the joint as well as potential damage to the tool itself. Conclusion:This is to our knowledge the first report on flexible videoarthroscopy. Some of the expectations were met, such as to reach virtually every corner the joint with minimal risk for the cartilage or other joint structures and with acceptable image quality. However, there are many significant disadvantages which question the routine use of such a videoendoscopic system with its present technical features.
Keywords: Arthroscopy, videoendoscopy, flexible, hip, knee
DOI: 10.3233/THC-2011-0657
Journal: Technology and Health Care, vol. 20, no. 2, pp. 127-133, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]