Authors: Wassilew, Georgi I.a; * | Janz, Viktora | Heller, Markusb | Wenzl, Marcusa | Perka, Carstena | Hasart, Olafa
Affiliations: [a] Charité, Universitätsmedizin Berlin, Center for Musculoskeletal Surgery Berlin, Orthopaedic Department, Berlin, Germany | [b] Charité, Universitätsmedizin Berlin, Julius Wolff Institute and Center for Musculoskeletal Surgery Berlin, Berlin, Germany
Correspondence: [*] Address for correspondence: Georgi I. Wassilew, MD, Charité, Universitätsmedizin Berlin, Center for Musculoskeletal Surgery Berlin, Orthopaedic Department, Charitéplatz 1, 10117 Berlin, Germany. Tel.: +49 30 450 615 179; Fax: +49 30 450 515 922; E-mail: [email protected].
Abstract: The purpose of our study was to develop a simple and reproducible method for calculating post-operative acetabular cup position based upon computed-tomographic images. Next, we sought to examine the reliability, objectivity and accuracy of this method. We developed a 3D CT evaluation software based upon Amira® (data visualisation, analysis and modelling software) to calculate the abduction and anteversion of the acetabular cup relative to the APP (anterior pelvic plane). To test the accuracy of the method, we constructed a special phantom pelvic model as the gold standard, in which the acetabulum was mounted at various abduction and anteversion angles that had previously been measured digitally. This phantom was then CT-scanned in 12 different cup positions (30° to 50° abduction, 0° to 30° anteversion) and then evaluated using the 3D CT evaluation software. In addition, we also examined the reliability and objectivity of this method in 10 patients following implantation of a hip prosthesis, as a clinical trial. We observed an average accuracy of the 3D CT evaluation software of −0.3° (range −1.4° to 1.3°; SD 0.6°) for abduction and 0.2° (range −1.4° to 1.4°; SD 0.6°) for anteversion compared with the gold standard. Moreover, a high intra- and inter-individual agreement in the resulting ICC well above 0.8 for abduction and abduction values in the phantom study and the clinical trial were observed. This study found that the 3D CT evaluation software provides high reliability, objectivity and accuracy. Thus, the 3D CT software is a method that permits very precise evaluation of the post-operative cup position independent of patient positioning or pelvic tilt.
Keywords: Acetabular cup orientation, 3D CT measurement, accuracy, phantom model
DOI: 10.3233/THC-2011-0629
Journal: Technology and Health Care, vol. 19, no. 3, pp. 185-193, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]