Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Momen, Kaveha; b; * | Fernie, Geoff R.b; c
Affiliations: [a] Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada | [b] iDAPT Technology R & D Team, Toronto Rehabilitation Institute, Toronto, Canada | [c] Department of Surgery, University of Toronto, Toronto, Canada
Correspondence: [*] Address for correspondence: Kaveh Momen, iDAPT Technology R & D Team, Toronto Rehabilitation Institute, 180 Elm Street, Toronto, ON, M5T 3M4 Canada. Tel.: +1 416 849 4340, ext: 221; Fax: +1 647 438 7150; E-mail: [email protected].
Abstract: It is estimated that 10% of the patients admitted to North American hospitals die of hospital acquired infections. Approximately half of these are thought to be a consequence of poor hand hygiene practices by the hospital staff. Electronic hand washing reminders that prompt caregivers to wash their hands before and after the patient/patient's environment contact may help to increase the hand hygiene compliance rate. However, the current systems fail to identify the nursing procedures happening around the patient to issue proper hand hygiene prompt. In this research we used the hardware of a low-cost wireless Sony game controller, which included a 3-axis accelerometer, to identify six nursing activities happening around a patient. We attached five sensors to eight nurses' left and right wrists, left and right upper arms, and the backs. Each nurse performed 10 trials of each nursing activity in sequence, followed by a combined nursing activities trial. We extracted mean, standard deviation, energy, and correlation among axes per sensor and compared the results of 1-Nearest Neighbour (1-NN), Decision Tree (J48), and Naïve Bayes classifiers. 1-NN classifier had the best performance and on average regardless of the sensor locations, we achieved 84% ± 2% accuracy.
Keywords: Infection control, hand hygiene, accelerometer, nursing activities Sony PlayStation, Sixaxis
DOI: 10.3233/THC-2010-0600
Journal: Technology and Health Care, vol. 18, no. 6, pp. 393-408, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]