Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Then, C.a; b | Menger, J.a; b | Benderoth, G.a; b | Alizadeh, M.d | Vogl, T. J.a; c | Hübner, F.a; c | Silber, G.a; b; *
Affiliations: [a] Center of Biomedical Engineering (CBME), Frankfurt/Main, Germany | [b] Institute for Materials Science, University of Applied Sciences Frankfurt/Main, Germany | [c] Department of Diagnostic and Interventional Radiology, Hospital of the Johann Wolfgang Goethe University Frankfurt/Main, Germany | [d] University of Science & Technology, Teheran, Iran
Correspondence: [*] Corresponding author. Tel.: +49 69 1533 3035; Fax: +49 69 1533 3030; E-mail: [email protected].
Abstract: Pressure sores are the most common complication associated with patient immobilization. They develop through sustained localized tissue strain and stress, primarily caused by body supports. Modifying support design can reduce the risk and extent of pressure sore development with computational simulations helping to provide insight into tissue stress-strain distribution. Appropriate material parameters for human soft tissue and support material, as well as precise anatomical modelling, are indispensable in this process. A finite element (FE) model of the human gluteal region based on magnetic resonance imaging (MRI) data has been developed. In vivo human gluteal skin/fat and muscle long-term material parameters as well as open-cell polyurethane foam support long-term material parameters have been characterised. The Ogden form for slightly compressible materials was employed to describe human gluteal soft tissue behaviour. Altering support geometries and support materials, effects on human gluteal soft tissue could be quantified. FE-analysis indicated maximal tissue stress at the muscle-bone interface, not at the skin. Shear strain maxima were found in the muscle layer near the fat-muscle interface. Maximum compressive stress magnitude at the sacral bone depended strongly on the behaviour of the pelvic diaphragm musculature. We hypothesize that the compliance of the muscles forming the pelvic diaphragm govern the relative motion of the buttock tissue to the adjacent bone structure under compression, thus influencing tissue stress magnitudes.
Keywords: Pressure sore, human gluteal soft tissue, stress and strain distribution, FE-simulation
DOI: 10.3233/THC-2008-16106
Journal: Technology and Health Care, vol. 16, no. 1, pp. 61-76, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]