Abstract: BACKGROUND: Four hemiplegia post-stroke patients with 10∘–30∘ genu recurvatum recruited for three-dimensional gait analysis to investigate optimum inclination in a Rigid Tuned Ankle Foot Orthosis (RT-AFO). OBJECTIVE: 1) To investigate the optimum inclination in a Rigid Tuned Ankle Foot Orthosis (RT-AFO) in order to stabilize stance knee kinematics in the sagittal plane for stroke patients with 10∘–30∘ genu recurvatum, and 2) to compare the effects of RT-AFO with different inclinations on spatio-temporal parameters. METHODS: Three dimensional gait measurements were performed in five conditions for four participants: walk without AFO (T1), walk with RT-AFO in 0∘ inclination (T2), walk with RT-AFO in 5∘ inclination (T3), walk with RT-AFO in 10∘ inclination (T4), and walk with RT-AFO in 15∘ inclination (T5). RESULT: Application of tibial inclination in the AFO reduced the genu recurvatum in participants who experienced stroke. Genu recurvatum was significantly reduced in conditions T3, T4 (p< 0.001) and in T5 (p< 0.05). Optimum inclination was found at 15∘ tibial inclination measured during mid-stance. This study reported a statistically significant improvement in cadence in condition T4 (RT-AFO 10∘) (p< 0.01). There were no significant results for improvement of walking speed and stride length. CONCLUSION: These results highlight the potential to optimize inclination of a Rigid Tuned Ankle Foot Orthosis for patients affected by stroke and also indicate the potential clinical applications of tuning the AFO in rehabilitation treatment of stroke patients.
Keywords: Ankle Foot Orthosis, optimum tibial inclination, post-stroke patient, genu recurvatum, tuning AFO
DOI: 10.3233/TAD-180211
Journal: Technology and Disability, vol. 31, no. 3, pp. 77-82, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]