Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: International Conference on Structural Engineering Dynamics – ICEDyn 2011
Article type: Research Article
Authors: Lallart, M. | Guyomar, D.
Affiliations: LGEF, INSA-Lyon, Villeurbanne, France | MATEIS, INSA-Lyon, Villeurbanne, France
Note: [] Corresponding author: M. Lallart, LGEF, INSA-Lyon, 8, rue de la Physique, F-69621, Villeurbanne, France. E-mail: [email protected]
Abstract: Recent trends in Structural Health Monitoring (SHM) systems have demonstrated the growing interest in autonomous, embeddable devices able to perform in-situ inspection and to work conjointly and wirelessly in a global sensor network. Hence, the energy aspect is of prior importance when dealing with such systems. However, most signal processing methods for assessing the integrity of a structure still rely on linear transforms or operators, such as Fourier or amplitude analysis, which for example require analog-to-digital converters that consume a lot of energy. As well, in addition of optimizing the signal processing, another important part is the use of a proper energy management for the whole system. Hence, the purpose of this paper is twofold. First, it aims at reviewing a particular set of low energy cost methods for Structural Health Monitoring consisting of deriving a Damage Index (DI) obtained from the comparison of the LW signature with a reference signal using logical operators that greatly reduce the required computational energy. A particular emphasis will be placed not only on the performance of the exposed techniques, but also on their energy consumption as well as their sensitivity and robustness facing environmental drifts. It will therefore be shown that the use of non-linear operators for the comparison permits ultra-low energy requirements while allowing detection abilities similar to classical approaches. The second objective of this paper is to discuss the implementation of the whole system in an efficient way using proper management strategies. This issue will be discussed through an example of a self-powered SHM scheme powered using ambient vibrations.
Keywords: Structural Health Monitoring, damage index, Lamb wave, low-power, self-powered
DOI: 10.3233/SAV-2012-0695
Journal: Shock and Vibration, vol. 19, no. 5, pp. 867-877, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]