Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Smajić, Miralema; * | Vujić, Zoricab
Affiliations: [a] Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Tuzla, Univerzitetska, Tuzla, Bosnia and Herzegovina | [b] Faculty of Pharmacy, Institute for Pharmaceutical Chemistry, University of Belgrade, Vojvode Stepe, Belgrade, Serbia
Correspondence: [*] Corresponding author: Miralem Smajić, Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Tuzla, Univerzitetska 8, 75000 Tuzla, Bosnia and Herzegovina. Tel.: +387 61 44 15 27; Fax: +387 35 320 991; E-mails: [email protected] and [email protected]).
Abstract: Central composite experimental design was used for fast, simple, and accurate high-performance liquid chromatography (HPLC) determination of hydrochlorothiazide, amlodipine and valsartan in combined dosage forms. This method avoids the disadvantages of the traditional analytical approach, which is time-consuming, involves a large number of runs, and does not allow establishing the multiple interacting parameters. On the basis of preliminary experiments and physicochemical characteristic of analyzed substances, three independent variables (methanol content, pH of the mobile phase, and column temperature) were selected as input, while as dependent variables, six responses (retention time of hydrochlorothiazide, retention time of amlodipine, retention time of valsartan, asymmetry of hydrochlorothiazide peak, asymmetry of amlodipine peak, and asymmetry of valsartan peak) were chosen. Face centered central composite design enables an estimation of factors which have the most importance. After optimizing experimental conditions, a separation was conducted on a Zorbax C8 (150 mm×4.6 mm, 5 μm) column with a mobile phase consisting of methanol-acetonitrile-acetate buffer 40:20:40 (v/v/v), pH adjusted to 3.5 with acetic acid, flow rate of 1 mL/min and column temperature of 40 degC. The method was successfully applied to the simultaneous separations of these active drug compounds in their commercial dosage forms.
Keywords: HPLC, central composite design, hydrochlorothiazide, amlodipine, valsartan
DOI: 10.3233/MGC-180259
Journal: Main Group Chemistry, vol. 17, no. 2, pp. 165-180, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]