Article type: Research Article
Authors: Chen, Ganga; b | Zhang, Zehuana; b | Xu, Shuoa; b | Jiang, Shiboa; b | Liu, Ximinga; b | Tang, Penga; b | Li, Songyuana; b | Xiang, Xinchenga; b; *
Affiliations: [a] Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, China | [b] Beijing Key Laboratory of Nuclear Detection & Measurement Technology, Beijing, China
Correspondence: [*] Corresponding author: Xincheng Xiang, E-mail: [email protected].
Abstract: BACKGROUND:The polychromatic X-rays generated by a linear accelerator (Linac) often result in noticeable hardening artifacts in images, posing a significant challenge to accurate defect identification. To address this issue, a simple yet effective approach is to introduce filters at the radiation source outlet. However, current methods are often empirical, lacking scientifically sound metrics. OBJECTIVE:This study introduces an innovative filter design method that optimizes filter performance by balancing the impact of ray intensity and energy on image quality. MATERIALS AND METHODS:Firstly, different spectra under various materials and thicknesses of filters were obtained using GEometry ANd Tracking (Geant4) simulation. Subsequently, these spectra and their corresponding incident photon counts were used as input sources to generate different reconstructed images. By comprehensively comparing the intensity differences and noise in images of defective and non-defective regions, along with considering hardening indicators, the optimal filter was determined. RESULTS:The optimized filter was applied to a Linac-based X-ray computed tomography (CT) detection system designed for identifying defects in graphite materials within high-temperature gas-cooled reactor (HTR), with defect dimensions of 2 mm. After adding the filter, the hardening effect reduced by 22%, and the Defect Contrast Index (DCI) reached 3.226. CONCLUSION:The filter designed based on the parameters of Average Difference (AD) and Defect Contrast Index (DCI) can effectively improve the quality of defect images.
Keywords: Linear accelerator, hardening artifacts, defect identification, filter design
DOI: 10.3233/XST-240032
Journal: Journal of X-Ray Science and Technology, vol. 32, no. 4, pp. 1137-1150, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]