Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Tawfik, Zyad A.a; b; * | Farid, Mohamed El-Azabb | El Shahat, Khaled M.c | Hussein, Ahmed A.b | Al Etreby, Mostafad; e
Affiliations: [a] Radiological Sciences Department, Inaya Medical Colleges, Riyadh, Saudi Arabia | [b] Physics Department, Faculty of Science, Assiut University, Assiut, Egypt | [c] Radiation Oncology Department, Faculty of Medicine, Al-Azhar University, Cairo, Egypt | [d] Oncology Department, Dr. Soliman Fakeeh Hospital | DSFH, Jeddah, Saudi Arabia | [e] Oncology Department, Cairo University Hospital, Cairo, Egypt
Correspondence: [*] Corresponding author: Zyad A. Tawfik, MS, Physics Department, Faculty of Science, Assiut University, Assiut, Egypt. Radiological Sciences Department, Inaya Medical College, Riyadh, KSA. Tel.: +966538165385; E-mail: [email protected]; ORCID: 0009-0004-3735-6665.
Abstract: BACKGROUND:SRS and SRT are precise treatments for brain metastases, delivering high doses while minimizing doses to nearby organs. Modern linear accelerators enable the precise delivery of SRS/SRT using different modalities like three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and Rapid Arc (RA). OBJECTIVE:This study aims to compare dosimetric differences and evaluate the effectiveness of 3DCRT, IMRT, and Rapid Arc techniques in SRS/SRT for brain metastases. METHODS:10 patients with brain metastases, 3 patients assigned for SRT, and 7 patients for SRS. For each patient, 3 treatment plans were generated using the Eclipse treatment planning system using different treatment modalities. RESULTS:No statistically significant differences were observed among the three techniques in the homogeneity index (HI), maximum D2%, and minimum D98% doses for the target, with a p > 0.05. The RA demonstrated a better conformity index of 1.14±0.25 than both IMRT 1.21±0.26 and 3DCRT 1.37±0.31. 3DCRT and IMRT had lower Gradient Index values compared to RA, suggesting that they achieved a better dose gradient than RA. The mean treatment time decreased by 26.2% and 10.3% for 3DCRT and RA, respectively, compared to IMRT. In organs at risk, 3DCRT had lower maximum doses than IMRT and RA, but some differences were not statistically significant. However, in the brain stem and brain tissues, RA exhibited lower maximum doses compared to IMRT and 3DCRT. Additionally, RA and IMRT had lower V15Gy, V12Gy, and V9Gy values compared to 3DCRT. CONCLUSION:While 3D-CRT delivered lower doses to organs at risk, RA and IMRT provided better conformity and target coverage. RA effectively controlled the maximum dose and irradiated volume of normal brain tissue. Overall, these findings indicate that 3DCRT, RA, and IMRT are suitable for treating brain metastases in SRS/SRT due to their improved dose conformity and target coverage while minimizing dose to healthy tissues.
Keywords: SRS, SRT, linac-based SRS, brain metastases, Rapid Arc, IMRT, 3DCRT
DOI: 10.3233/XST-230275
Journal: Journal of X-Ray Science and Technology, vol. 32, no. 3, pp. 765-781, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]