Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhi, Weijuana | Zou, Jinga; * | Zhao, Jintaob | Xia, Xiaoqinc
Affiliations: [a] The State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China | [b] Tianjin Key Laboratory of Information Sensing and Intelligent Control, Tianjin University of Technology and Education, Tianjin, China | [c] College of Mathematical Medicine, Zhejiang Normal University, Jinhua, China
Correspondence: [*] Corresponding author. Jing Zou, The State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300000, China. Tel.: 0086 18622018987; E-mail: [email protected].
Abstract: BACKGROUND:Dual-energy computed tomography (DECT) can reconstruct electron density ρe and effective atomic number Zeff distribution for material discrimination. Image-domain basis material decomposition (IBMD) method is a widely used DECT method. However, IBMD method cannot be used for mineral identification directly due to limitations of complex basis material determination, beam hardening artifacts, and inherent errors caused by approximate empirical formulas. OBJECTIVE:This study proposes an improved IBMD (IIBMD) method to overcome the above limitations. METHODS:In IIBMD method, the composition of basis material is optimized to obtain accurate decomposition coefficients, which enables accurate ρe and Zeff distribution. Moreover, the thickness of basis material is optimized to reduce the effect of beam hardening. Furthermore, two formulas in place of empirical formulas are proposed to calculate ρe and Zeff. Finally, a threshold technique is applied to separate different mineral phases. RESULTS:Numerical simulations and practical experiments using a photon-counting detector CT system are implemented to verify IIBMD method. Results show that the relative errors of ρe and Zeff for seven common minerals are down to 5%, lower than most of the existing DECT methods for rocks. Reasonable volume fraction results of mineral phases are thus obtained through threshold segmentation. CONCLUSIONS:This study demonstrates that the proposed IIBMD method has high practical value in mineralogical identification.
Keywords: Dual-energy computed tomography, basis material decomposition, mineral quantitative characterization, basis material determination
DOI: 10.3233/XST-221324
Journal: Journal of X-Ray Science and Technology, vol. 31, no. 2, pp. 373-391, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]