Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Byun, Sohyuna | Jung, Julipa | Hong, Helena; * | Kim, Bong-Seogb
Affiliations: [a] Department of Software Convergence, Seoul Women’s University, Seoul, Republic of Korea | [b] R&D Center, Boryung Ltd., Seoul, Republic of Korea
Correspondence: [*] Corresponding author: Helen Hong, Department of Software Convergence, Seoul Women’s University, 621 Hwarang-Ro, Nowon-Gu, Seoul 01797, Republic of Korea. Tel.: +82 2 970 5756; Fax: +82 2 970 5981; E-mail: [email protected].
Abstract: BACKGROUND:Volumetric lung tumor segmentation is difficult due to the diversity of the sizes, locations and shapes of lung tumors, as well as the similarity in the intensity with surrounding tissue structures. OBJECTIVE:We propose a dual-coupling net for accurate lung tumor segmentation in chest CT images regardless of sizes, locations and shapes of lung tumors. METHODSTo extract shape information from lung tumors and use it as shape prior, three-planar images including axial, coronal, and sagittal planes are trained on 2D-Nets. Two types of window images, lung and mediastinal window images, are trained on 2D-Nets to distinguish lung tumors from the thoracic region and to better separate the boundaries of lung tumors from adjacent tissue structures. To prevent false-positive outliers to adjacent structures and to consider the spatial information of lung tumors, pairs of tumor volume-of-interest (VOI) and tumor shape prior are trained on 3D-Net. RESULTSIn the first experiment, the dual-coupling net had the highest Dice Similarity Coefficient (DSC) of 75.7%, considering the shape prior as well as mediastinal window images to prevent the leakage of adjacent structures while maintaining the shape of the lung tumor, with 18.23% p, 3.7% p, 1.1% p, and 1.77% p higher DSCs than in the 2D-Net, 2.5D-Net, 3D-Net, and single-coupling net results, respectively. In the second experiment with annotations for two clinicians, the dual-coupling net showed outcomes of 67.73% and 65.07% regarding the DSC for each annotation. In the third experiment, the dual-coupling net showed 70.97% for the DSC. CONCLUSIONSThe dual-coupling net enables accurate segmentation by distinguishing lung tumors from surrounding tissue structures and thus yields the highest DSC value.
Keywords: Chest computed tomography (CT), lung tumor segmentation, deep learning, shape prior, mediastinal window image
DOI: 10.3233/XST-221191
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 6, pp. 1067-1083, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]