Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Dong, Taoa; b | Zhang, Huaxiaa; b | Wu, Zhifanga; b; *
Affiliations: [a] Institute of Nuclear Energy and New Energy Technology, Tsinghua University, Beijing, China | [b] Beijing Key Laboratory on Nuclear Detection & Measurement Technology, Beijing, China
Correspondence: [*] Corresponding author: Zhifang Wu, Institute of Nuclear Energy and New Energy Technology, Tsinghua University, Beijing, 100084, China. E-mail: [email protected].
Abstract: BACKGROUND:The detectors of existing large object radiation imaging systems generally work under current-integration mode and cannot distinguish effective signals of unreacted photons from interfering signals of electronic noise and scattered photons, therefore, resulting in image quality deterioration. OBJECTIVE:This study aims to design a new photon-counting mode γ-ray large object radiation imaging system. Therefore, interfering signals with lower energy than effective signals can be eliminated by energy analysis. In addition, the system enables to work properly even under 30∼300Ci Co-60 intensity. METHODS:Based on the physical analysis of the system, the design requirements are listed. Following the requirements, the best-performing photon-counting detector based on LYSO and SiPM is used in the system. ZP-SK and (ZP)2-SK filter circuits are designed for Co-60 radiation imaging system with the highest intensity of 100Ci and 300Ci, respectively. Then, a voltage comparator and an FPGA are followed to realize the function of energy analysis and photon counting. RESULTS:The proposed technical solution can improve the Steel Penetration (SP) by at least 60∼70 mmFe compared with the existing current-integration system, which is equivalent to the improvement obtained by increasing the intensity of the radioactive source more than 13 to 20 times. CONCLUSIONS:This study demonstrates the advantages of applying the new photon-counting mode γ-ray large object radiation imaging system to improve the radiation image quality and the penetration ability, which will have enormous potential for future applications.
Keywords: Photon-counting mode, radiation imaging system, electronics circuits, Steel Penetration
DOI: 10.3233/XST-221185
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 4, pp. 789-804, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]