Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Priyanka, a | Kadavigere, Rajagopalb; * | Sukumar, Suresha
Affiliations: [a] Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India | [b] Department of Radio diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India
Correspondence: [*] Corresponding author: Dr. Rajagopal Kadavigere, Department of Radio diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal–576104, India. Tel.: +91 9448158901; E-mail: [email protected].
Abstract: BACKGROUND:Pediatric population is more sensitive to the effects of radiation than adults. Establishing diagnostic reference level (DRL) is an efficient dose optimization technique implemented by many countries for reducing radiation dose during Computed Tomography (CT) examinations. OBJECTIVES:To estimate radiation dose and establish a new local diagnostic reference level for CT head examination in the pediatric population. MATERIALS AND METHODS:We prospectively recruited 143 pediatric patients referred for CT head examination with age ranging from 0–5 years old. All patients had undergone CT head examination using the standard pediatric head protocol. Volumetric CT dose index (CTDIvol) and dose length product (DLP) were recorded. The effective dose was first calculated. Then, 75th percentile of dose indices was calculated to establish DRLs. RESULTS:DRLs in terms of CTDIvol and DLP are 23.84 mGy, 555.99 mGy.cm for patients <1 years old and 28.65 mGy, 794.99 mGy.cm for patients from 1–5 years old, respectively. Mean effective doses for <1 years old patients and 1–5 years old patients are 2.91 mSv and 2.78 mSv respectively. CONCLUSION:The study concludes that DRL in terms of CTDIvol is lower but DRL in terms of DLP and the effective dose is higher compared to a few other studies which necessitate the need for dose optimization.
Keywords: Diagnostic reference levels, pediatric computed tomography, volumetric computed tomography dose index, dose length product, effective dose estimation
DOI: 10.3233/XST-221172
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 5, pp. 983-991, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]