Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Qian, Wena; 1 | Liu, Wangyana; 1 | Zhu, Yinsua | Wang, Juna | Chen, Yanga | Meng, Haoyub | Chen, Leileib | Xu, Yia; 2; * | Zhu, Xiaomeia; 2; *
Affiliations: [a] Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China | [b] Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
Correspondence: [*] Corresponding authors: Xiaomei Zhu, MD, PhD, Associated professor Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd., Nanjing, Postcode: 210029; China. Tel.: +8613770346260; E-mail: [email protected] and Yi Xu, MD, PhD, Associated professor Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd., Nanjing, Postcode: 210029; China. Tel.: +8613951891760; E-mail: [email protected].
Note: [1] These authors contributed equally to this work.
Note: [2] These authors are co-communicating authors.
Abstract: BACKGROUND:CT-derived fractional flow reserve (FFRCT) and diagnostic accuracy rely on good image quality during coronary CT angiography (CCTA). OBJECTIVE:To investigate whether heart rate (HR) and coronary artery calcium (CAC) score decrease image quality and diagnostic performance of two advanced CT scanners including 96-row detector dual source CT (DSCT) and 256-row multidetector CT (MDCT). METHODS:First, 79 patients who underwent CCTA (42 with DSCT and 37 with MDCT) and invasive coronary angiography (ICA) are enrolled. Next, coronary segments with excellent image quality are evaluated and the percentage is calculated. Then, diagnostic accuracy in detecting significant diameter stenosis is presented with ICA as the reference standard. RESULTS:Compared with the DSCT, the percentage of coronary segments with excellent image quality is lower (P = 0.010) while diagnostic accuracy on per-segment level is improved (P = 0.037) using MDCT. CAC score≥400 is the only independent factor influencing the percentage of coronary segments with excellent image quality [odds ratio (OR): DSCT, 3.096 and MDCT, 1.982] and segmental diagnostic accuracy (OR: DSCT, 2.630 and MDCT, 2.336) for both scanners. HR≥70 bpm (OR: 5.506) is the independent factor influencing the percentage of coronary segments with excellent image quality with MDCT. CONCLULSION:During CCTA, CAC score≥400 still decreases the proportion of coronary segments with excellent image quality and diagnostic accuracy with advanced CT scanners. HR≥70 bpm is another factor causing image quality decreasing with MDCT.
Keywords: Coronary angiography, coronary stenosis, multidetector computed tomography, calcium, heart rate
DOI: 10.3233/XST-210837
Journal: Journal of X-Ray Science and Technology, vol. 29, no. 3, pp. 529-539, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]