Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhao, Yongxiaa; * | Geng, Xueb | Zhang, Tianleb | Wang, Xiuzhib | Xue, Yizeb | Dong, Kexinb
Affiliations: [a] Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China | [b] College of Medicine, Hebei University, Baoding, China
Correspondence: [*] Corresponding author: Yongxia Zhao, PhD., Department of Radiology, The Affiliated Hospital of Hebei University, 212 Yuhua Road, Lianchi District, Baoding City, Hebei Province, 300072, China. Tel.: +86 15131221591; E-mail: [email protected].
Abstract: OBJECTIVE:To compare image quality, radiation dose, and iodine intake of head-neck CT angiography (CTA) acquired by wide-detector with the gemstone spectral imaging (GSI) combination with low iodine intake or routine scan protocol. METHODS:Three hundred patients who had head-neck CTA were enrolled and divided into three groups according to their BMI values: group A (18.5 kg/m2 ≦ BMI <24.9 kg/m2), group B (24.9 kg/m2 ≦ BMI <29.9 kg/m2) and group C (29.9 kg/m2 ≦ BMI ≦ 34.9 kg/m2) with 100 patients in each group. Patients in each group were randomly divided into two subgroups (n = 50) namely, A1, A2, B1, B2, C1 and C2. The patients in subgroups A1, B1 and C1 underwent GSI with low iodine intake (270 mgI/ml, 50 ml) and combined with the ASiR-V algorithm. Other patients underwent three dimensional (3D) smart mA modulation with routine iodine intake (350 mgI/ml, 60 ml). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated after angiography. Images were then subjectively assessed using a 5-point scale. CT dose index of volume and dose-length product (DLP) was converted to the effective dose (ED) and then compared. RESULTS:The mean CT values, SNR, CNR and subjective image quality in subgroups A2, B2 and C2 are significantly lower than in subgroups A1, B1, and C1 (P < 0.01), respectively. The ED values in subgroup A1, B1, and C1 are 55.18%, 61.89%, and 69.64% lower than those in A2, B2, and C2, respectively (P < 0.01). The total iodine intakes in subgroups A1, B1, and C1 are 35.72% lower than those in subgroups A2, B2, and C2. CONCLUSIONS:The gemstone spectral imaging with monochromatic images at 53–57 keV combined with ASiR-V algorithm allows significant reduction in iodine load and radiation dose in head-neck CT angiography than those yielded in routine scan protocol. It also enhances signal intensity of head-neck CTA and maintains image quality.
Keywords: Gemstone spectral imaging, radiation dose, image quality, low iodine intake, head-neck CT angiography
DOI: 10.3233/XST-190541
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 5, pp. 981-993, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]