Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Gupta, Ruchia; * | Sinha, Neetua | Kumar, Prema | Bhadani, Punamb | Rai, Deependra Kumarc | Kumar, Subhasha
Affiliations: [a] Department of Radiodiagnosis, AIIMS Patna, Phulwarisharif, Bihar, India | [b] Department of Pathology, AIIMS Patna, Phulwarisharif, Bihar, India | [c] Department of Pulmonary Medicine, AIIMS Patna, Phulwarisharif, Bihar, India
Correspondence: [*] Corresponding author: Dr. Ruchi Gupta, Senior Resident, Department of Radiodiagnosis, AIIMS Patna, Room no 706, PG 1 Hostel, AIIMS Patna, Phulwarisharif, Bihar, 801507, India. Tel.: +91 9718407808; E-mail: [email protected].
Abstract: OBJECTIVE:Intermittent CT fluoroscopic biopsy is a new technology, but has not been studied widely. This study aims to investigate correlation between the radiation dose and fluoroscopic CT exposure factors to establish the low dose parameters for performing percutaneous lung biopsies, as well as the relationship of the mean diameter and depth of lesions with radiation dose, procedure time, success and complication rates. MATERIALS AND METHODS:This is a retrospective study to analyse lung biopsies performed using intermittent CT fluoroscopic technique with 18 G semi-automated coaxial gun on 256 slice scanner. A total of 50 patients were included in the study. Biopsy was done in three mAs and KVp settings (30 and 70, 10 and 120, 30 and 120, respectively). The statistical data analysis was performed using SPSS Statistics software. RESULTS:Pneumothorax occurred in 22 % of cases. Sampling rate was 98% but histopathological diagnosis was made in 94% cases. Mean procedure time was 30.5±11.1 minutes. Low dose protocol (30 mAs and 70 KVp) had least radiation exposure during biopsy procedure (p < 0.001) with similar success rate, complications and procedure time (p > 0.05) in comparison with high dose protocol (10 and 120, 30 and 120 mAs and KVp, respectively). Mean diameter of lesions didn’t correlate with radiation dose, success rate, complications and duration of procedure (p > 0.05) while significant association was found when depth was correlated with radiation exposure during fluoroscopic biopsy, duration of procedure and complication rates (p < 0.05) while no association was found with success rates. CONCLUSION:On third generation dual energy source CT scanner, reducing mAs and KVp to 30 and 70 during fluoroscopy biopsy can produce images whose complications and success rates are comparable to high dose CT. In general, intermittent CT fluoroscopy guided lung biopsy has good success rates with acceptable complications, while utilising less radiation dose and procedure time.
Keywords: Computed tomography (CT), intermittent, fluoroscopy, biopsy, lung, radiation, dose length product (DLP)
DOI: 10.3233/XST-180424
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 2, pp. 287-296, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]