Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hayashi, Norioa; * | Yarita, Kazumab | Sakata, Kozuec | Motegi, Shunichid | Nagase, Hiroyukie | Ujita, Kouichib | Ogura, Akioa | Ogura, Toshihiroa | Shimada, Takehirof | Tsushima, Yoshitof
Affiliations: [a] Department of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Japan | [b] Department of Radiology, Gunma University Hospital, Maebashi, Japan | [c] Department of Radiology, IMS Ohta Chuo General Hospital, Ohta, Japan | [d] Department of Radiology, Josai Clinic, Maebashi, Japan | [e] Department of Radiology, Maebashi Red Cross Hospital, Maebashi, Japan | [f] Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, Maebashi, Japan
Correspondence: [*] Corresponding author: Norio Hayashi, Department of Radiological Technology, Gunma Prefectural College of Health Sciences, 323-1 Kamioki, Maebashi, Gunma 371-0052, Japan. Tel.: +81 27 235 1211; Fax: +81 27 235 2501; E-mail: [email protected].
Abstract: BACKGROUND:Optimizing scan parameters for double inversion recovery (DIR) sequences remains difficult. OBJECTIVE:To evaluate a new method for optimizing DIR sequence scan parameters using T1 mapping and a newly developed analysis algorithm. METHODS:Twelve healthy volunteers underwent T1 mapping and DIR magnetic resonance imaging. The following steps were used for image optimization including: 1) measurement of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) T1 values to create a T1 map; 2) calculation of optimized scan parameters by using a developed analysis algorithm; 3) performance assessment of DIR magnetic resonance imaging by using the calculated optimized imaging parameters. Additionally, we used scan parameters from previous studies to obtain DIR images in order to evaluate our new method. The contrast between GM and suppressed tissues was compared between these images and those obtained using the optimized parameters. RESULTS:Using our optimization method, WM and CSF regions were suppressed uniformly for all scan conditions. The contrast was significantly higher in images obtained using this optimization method compared to those obtained using previously published parameters (p < 0.01). CONCLUSIONS:It is possible to obtain superior DIR images by using an optimization method that involves T1 mapping and a newly developed analysis algorithm.
Keywords: MRI, brain, DIR, T1 map, WAIR
DOI: 10.3233/XST-16243
Journal: Journal of X-Ray Science and Technology, vol. 25, no. 5, pp. 803-812, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]