Article type: Research Article
Authors: Zhang, Yuana | Zhang, Liyia; b; * | Sun, Yunshanb
Affiliations: [a] School of Electronic Information Engineering, Tianjin University, Tianjin, China | [b] School of Information Engineering, Tianjin University of Commerce, Tianjin, China
Correspondence: [*] Corresponding author: Dr. Liyi Zhang, Ph.D., School of Electronic Information Engineering, Tianjin University, Tianjin, China. Tel.: +86 022 26675771; Fax: +86 022 26675771; E-mail: [email protected].
Abstract: BACKGROUND:It is often unrealistic to assume that the subject remains stationary during a computed tomography (CT) imaging scan. A patient rigid motion can be decomposed into a translation and a rotation around an origin. How to minimize the motion impact on image quality is important. OBJECTIVE:To eliminate artifacts caused by patient rigid motion during a CT scan, this study investigated a new method based on frequency domain analysis to estimate and compensate motion impact. METHODS:Motion parameters was first determined by the magnitude correlation of projections in frequency domain. Then, the estimated parameters were applied to compensate for the motion effects in the reconstruction process. Finally, this method was extended to helical CT. RESULTS:In fan-beam CT experiments, the simulation results showed that the proposed method was more accurate and faster on the performance of motion estimation than using Helgason-Ludwig consistency condition method (HLCC). Furthermore, the reconstructed images on both simulated and human head experiments indicated that the proposed method yielded superior results in artifact reduction. CONCLUSIONS:The proposed method is a new tool for patient motion compensation, with a potential for practical application. It is not only applicable to motion correction in fan-beam CT imaging, but also to helical CT.
Keywords: CT, fan-beam, frequency domain, motion artifacts
DOI: 10.3233/XST-16193
Journal: Journal of X-Ray Science and Technology, vol. 25, no. 5, pp. 721-736, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]