Article type: Research Article
Authors: Tokala, Krishna T. | Piao, Daqing | Xu, Guan
Affiliations: School of Electrical and Computer Engineering, Oklahoma State University, Stillwater, OK, USA | Department of Radiology, Medical School, University of Michigan, Ann Arbor, MI, USA
Note: [] Corresponding author: Daqing Piao, School of Electrical and Computer Engineering, Oklahoma State University, Stillwater, OK 74078, USA. E-mail: [email protected]
Abstract: A geometric-sensitivity-difference (GSD) based reconstruction method is demonstrated in fluorescence diffuse optical tomography (FDOT) for improving the depth-localization of objects. The GSD method optimizes the data-model fit based on paired-measurements between source-detector pairs sharing either the source or the detector channel, as comparing to conventional methods that optimize the data-model fit based on un-paired measurements of individual source-detector pairs. This in silico study is limited to continuous-wave and 2-dimension, for a circular-array outward-imaging geometry of which the native sensitivity of measurement varies strongly with respect to the depth of the object. The outcomes of GSD method are compared to that of two conventional methods: one is the baseline method which does not involve any scheme to compensate the variation of native sensitivity; the other applies a depth-adapted weight to counteract the depth-variance of the native sensitivity. These three methods were evaluated using synthetic data corresponding to the following conditions of the object: (1) Single object with a 3-folds of positive contrast of fluorescence over the background was set at edge-depths of 0.5 mm, 5 mm and 10 mm; (2) Two objects with identical 3-folds of positive or 1/3-folds of negative contrast of fluorescence over the background were set at a fixed edge-depth of 10 mm and different azimuthal separations of 45 degree, 135 degree, and 180 degree; (3) Two objects with identical 3-folds of positive or 1/3-folds of negative contrast of fluorescence over the background were set at a fixed azimuthal separation of 90° and at edge-depths of 0.5 mm, 5 mm and 10 mm. The GSD method outperforms the other two methods in localizing a single anomaly and resolving two anomalies, for the anomaly possessing either the 3 folds positive or 1/3-folds negative contrast of fluorescence over the background. The case of objects with negative contrast over the background has specific implications to imaging zinc-specific fluorophore uptake in prostate.
Keywords: Fluorescence diffuse optical tomography, image reconstruction, continuous-wave, sensitive matrix, geometric-sensitivity-difference
DOI: 10.3233/XST-140450
Journal: Journal of X-Ray Science and Technology, vol. 22, no. 5, pp. 627-643, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]