Authors: El-Gebaly, Reem H. | Maamoun, Islam K. | Madian, Noha G.
Affiliations: Department of Biophysics, Faculty of Science, Cairo University, Cairo, Egypt | Nuclear Cardiology Department, Intensive Care Unit, Faculty of Medicine, Cairo University Hospitals, Cairo, Egypt
Note: [] Corresponding author: Reem H. El-Gebaly, Department of Biophysics, Faculty of Science, Cairo University, Cairo, Egypt. E-mail: [email protected]
Abstract: BACKGROUND: Myocardial perfusion imaging (MPI) can provide the valuable cardiac functions.Image quality in nuclear medicine tomography is critically dependent on the activity administered into patients. OBJECTIVE: This study was designed to evaluate the optimum injected dose of 99mTc-MIBI for quantitative assessment of image quality as compared with standard injected dose used for that purpose. METHODS: The image quality parameters (Contrast, relative noise and contrast to noise ratio) were determined in 32 patients (21 male, 11 female, age 45–60 y) with weight 60 ± 15 kg. Patients were classified into four groups; each one consisted of 8 patients. The first group received 370 MBq, the second one received 555 MBq, the third group received 740 MBq and the last group received 925 MBq. RESULTS: Qualitative assessments of the images revealed equivalent scintigraphic patterns in all patients. There was a significant difference in the image contrast. The image contrast in the 370 MBq group was greater than other groups. The image noise between the four groups was significantly different. It increased with injected dose reduction. Contrast to noise ratio (CNR) was significantly different between 370 MBq and other groups. CONCLUSION: It is concluded that results from the first group which received 370 MBq are sufficiently similar to those of the fourth group (standard group) which received 925 MBq. Consequently,accurate estimations of differential cardiac functions are possible with the 370 MBq dose.
Keywords: 99mTc-MIBI, image quality parameters, image quality, qualitative assessment, image contrast, image noise
DOI: 10.3233/XST-140443
Journal: Journal of X-Ray Science and Technology, vol. 22, no. 4, pp. 529-537, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]